CONTENTS
Contents……………………………………………...........   2
Introduction………………………………………….   2
Specifications………………………………………..   2
Safety Rules…………………………………………   3
Helpful Installation Information……………….........….   3
Connecting the Vent……………………………....…..… 3,4
Combustion and Ventilation Air......................................   5
Furnace Location………………………………….....….   6
Rough-In Instructions…………………………..…..…. 6,7
Installation……………………………………….......…..   8
Controls…………………………………………........…..   9
Pilot Flame Adjustment…………………………......…..   9
Lighting & Re-Lighting Instructions……………….. 10,11
Operation………………………………………….....….
12
Terminal Block Wiring Diagram……………….....……
13
Manual Reset…………………………………....……..
13
Maintenance Instructions…………………….………
13
Wiring Diagram……………………………….....…….. 14,15
Side & Rear Discharge Kits……………………...……16,17
Trouble Shooting Chart…………………………..….. 18,19
Repair Parts (break down)………………………..….. 20-24
Repair Parts List…………………………………....…. 21-25
Warranty………………………………………….....….
27
INSTALLER MUST LEAVE THESE INSTRUCTIONS WITH THE CONSUMER, HAVE THEM
COMPLETE, AND RETURN THE WARRANTY CARD.
INTRODUCTION
THIS IS A GAS-FIRED, GRAVITY VENTED WALL FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN
EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE
INSTALLATION AND OPERATING INSTRUCTIONS.  READ THESE INSTRUCTIONS THOROUGHLY BEFORE
INSTALLING, SERVICING, OR USING THE APPLIANCE.  IF YOU DO NOT UNDERSTAND ANY PART OF THESE
INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE AGENCIES, THE
GAS SUPPLIER, OR THE MANUFACTURER.
COUNTERFLOW WALL FURNACE SPECIFICATIONS
Your counterflow wall furnace is packed in a single carton that also includes thermostat, thermostat wire, and insulated staples.
The thermostat, wire, and staples are packed in the burner compartment and are accessible by removing the burner access door.
While the burner access door is open, check the rating plate to verify that the model number is correct and that the wall furnace
is equipped for the type gas you intend to use.
Vent
Approx.
Model
Type
  Type
BTU/HR.
Size
Gas
  Blower
Shipping
Number Control   Gas
Input
(Oval)
Inlet
Finished Dimensions
  Speed   Amps CFM
Weight
MODELS WITH LOW-BTU STANDING PILOT
CF353C-H  24 Volt  Nat.
35,000
4”
½”     14-5/16”Wx10¼”Dx78-5/8”H       1
  1.95
320
  95 Lbs.
CF354C-H  24 Volt  L.P.
35,000
4”
½”     14-5/16”Wx10¼”Dx78-5/8”H       1
  1.95
320
  95 Lbs.
CF503C-H  24 Volt  Nat.
50,000
4”
½”     14-5/16”Wx10¼”Dx81-5/16”H     2
  2.25
440
104 Lbs.
CF504C-H  24 Volt  L.P.
50,000
4”
½”     14-5/16”Wx10¼”Dx81-5/16”H     2
  2.25
440
104 Lbs.
CF653C-H  24 Volt  Nat.
65,000
4”
½”     14-5/16”Wx10¼”Dx87-5/16”H     2
  2.25
440
107 Lbs.
CF654C-H  24 Volt  L.P.
65,000
4”
½”     14-5/16”Wx10¼”Dx87-5/16”H     2
  2.25
440
107 lbs.
MODELS WITH INTERMITTENT IGNITION
CF357C-H   24 Volt  Nat.
35,000
4”
½”     14-5/16”Wx10¼”Dx78-5/8” H      1
2.2
320
  95 Lbs.
CF358C-H   24 Volt  L.P.
35,000
4”
½”     14-5/16”Wx10¼”Dx78-5/8”H       1
2.25
320
  95 Lbs.
CF557C-H   24 Volt  Nat.
55,000
4”
½”     14-5/16”Wx10¼”Dx87-5/16”H     2
2.5
440
107 Lbs.
CF558C-H   24 Volt  L.P.
55,000
4”
½”     14-5/16”Wx10¼”Dx87-5/16”H     2
2.55
440
107 Lbs.
Page 2