Sterling SDA 1000-5100 Manual Do Utilizador

Página de 61
Large Dehumidifying Dryers  
Controls 
29 
Identifying Temperature Controller Keys 
Indicator 
Name 
Description 
 
 
Mode Key 
Press the Mode key to shift the display to the next 
set of parameters. The menu screen displays. 
 
 
Down Key 
Press the Down arrow key to lower the process air 
set point temperature. During setup, it lets you 
decrease the value of the parameter displayed on 
the set point LED readout. 
 
 
Up Key 
Press the Up arrow key to raise the process air set 
point temperature. During setup, it lets you 
increase the value of the parameter displayed on 
the set point LED readout. 
Setting the Process Air Temperature 
When setting the process air temperature, consult with the resin manufacture for the 
recommended drying temperature. 
To change the process air temperature set point with the dryer running: 
 
Press 
 to raise the set point to the temperature you want. 
 
Press 
 to lower the set point to the temperature you want. 
Restoring the Process Air Temperature Controller (E5CN) to Factory Settings 
If the preset parameters on the controller have been tampered with and it no longer properly 
controls temperature and displays dew point, you can restore the controllers to the factory 
setup.  Call the Service Department for detailed instructions. 
E5CN Operating Parameters 
The E5CN controller has several mode selections. Within each mode are numerous 
parameters that can be set. 
The factory has set the security level to protect the critical parameters from being accidentally 
changed. Below is an explanation of the operating modes you will have access to and on the 
following page are the manufacturers’ default settings.