Sterling SDA 1000-5100 Manual Do Utilizador

Página de 61
Large Dehumidifying Dryers 
Operation 
36 
5-2   Dryer Operation Procedures  
Controller Operation  (Without Optional Alarm Horn & Reset Button) 
1.  Turn the disconnect on the control panel to the ON position.  Power is applied to the 
voltage line fuses, line side of the control power switch and the temperature 
controller. 
2.  Turn the control power switch to the ON position.  Power is applied to the 
programmable relay and dew point controller.  The valve will move to the start 
position as follows: 
a.  The bed switch valve motor rotates until the cam switch makes 2 transitions.  
b.  If the cam switch does not make a transition within 10 seconds, a valve 
motor fault is generated.  “VM” is displayed on the relay screen, the alarm 
light is activated.  The valve motor, heaters, and blower shut off.   
To restart the dryer, cycle control power to deactivate the alarm light and 
restart the valve motor sequence. 
Note: 
The relay screen which contains the Alarm Display Messages is 
located inside the controller enclosure.  For a list of Alarm Display 
Messages, see Page 39. 
WARNING!  Do not attempt to check the Alarms on the Controller located within the 
unit enclosure unless you are a qualified electrician! 
 
 
c.  The valve will normally complete one full cycle (revolution). 
If the drying process shuts down due to an alarm, the dryer has been setup to 
have the following operational features: 
•  The bed in process at power-down will remain in process. 
•  The bed in regeneration at power-down will remain in regeneration. 
•  The regeneration timing cycle will restart from the beginning. 
3.  Once the control power is on and no fault conditions exist, turning the OFF-ON-
START switch to the START position will start the dryer as follows: 
a.  The process heater is turned on and controlled by the E5CN controller. 
b.  The process & regen blowers are started. 
c.  The regen heater is turned on and the regeneration timing sequence is 
initiated.  The regen heater is controlled by the E5CN controller.  For default 
timing settings for regeneration, see the table below. 
4.  If either the left or right bed safety temperature switch opens, a regen heater fault is 
generated.  “RS” is displayed on the relay screen.  The alarm light is activated.  The 
process heater, regen heater, and process/regen blowers are turned off.   
Turn the OFF-ON-START switch to the START position to deactivate the alarm 
light and restart the dryer.  If either switch is still open, the dryer will not restart.