Chapter 4: Operation 
27 of 59 
 
Indicator 
Name 
Description 
ALARM1 
ALARM 1 LED 
Lights in the Operation Indicator Section when 
the output function assigned to auxiliary output 
1 turns on.  
The ALARM1 indicator lights when 
the process temperature exceeds the set point 
temperature by more than the alarm deviation 
value. Alarm output de-energizes the heaters. 
Heaters re-energize when the temperature falls 
within the acceptable range. 
 
Identifying Temperature Controller Keys 
Indicator 
Name 
Description 
 
Mode Key 
Press the Mode key to shift the display to the next 
set of parameters. The menu screen displays. 
 
Down Key 
Press the Down arrow key to lower the process air 
set point temperature. During setup, it lets you 
decrease the value of the parameter displayed on 
the set point LED readout. 
 
Up Key 
Press the Up arrow key to raise the process air set 
point temperature. During setup, it lets you 
increase the value of the parameter displayed on 
the set point LED readout. 
Setting the Process Air Temperature 
When setting the process air temperature, consult with the resin manufacture for the 
recommended drying temperature. 
To change the process air temperature set point with the dryer running: 
•  Press 
 to raise the set point to the temperature you want. 
•  Press 
 to lower the set point to the temperature you want.