Sterling SDA 150-380 Manual Do Utilizador

Página de 52
 
 
Cabinet Series Dehumidifying Dryer 
 
49 
Problem  
Possible cause  
Corrective action 
Airflow valve sticking or 
failing to shift. 
Check for proper operation of 
valve actuators. Repair or 
replace if necessary. 
Loss or reduction in drying 
capacity. (Cont’d.) 
Blower fins filled with dust or 
contaminants. 
Remove blower side plate, 
clean baffles, replace. 
Replace filter elements. 
Insufficient power to PLC 
(Power LED is off). 
Check power supply and 
power wiring to PLC. 
PLC Regeneration Bed LED 
indicators both off. 
Faulty PLC (PLC Power light 
is on, Run light is off, and/or 
Error light is on). 
Replace PLC. 
Regenerating bed cool down.  None. 
Blower Input indicator is off. 
Verify that blower contactor is 
on. Check input wiring to 
PLC. 
Process air in high-
temperature condition. 
None. 
Insufficient power to PLC 
(Power light is off). 
Check power supply and 
power wiring to PLC. 
PLC Regeneration Heater 
Left/Right output indicators 
both off. 
Faulty PLC (PLC Power light 
is on, Run light is off, and/or 
Error light is on). 
Replace PLC. 
Process temperature set too 
high due to operator error. 
Check resin manufacturer’s 
data sheet for proper drying 
temperature. Make sure plant 
personnel are aware of the 
correct process temperature 
set point. 
High temperature alarm not 
set properly. 
Reset high temperature 
alarm. 
Process set point is out of 
acceptable range. 
Restore temperature 
controller to factory pre-sets. 
Material in drying hopper 
cakes, or meltdown occurs. 
 
Function set for degrees 
Celsius (ºC), set point at 
degrees Fahrenheit (ºF). 
Verify correct Celsius or 
Fahrenheit settings. 
Burned out regeneration 
heater. 
Repair or replace. 
Contaminated or worn out 
desiccant. 
Replace. 
Leaking process air hoses. 
Repair or replace. 
Dryer operates beyond its 
capacity. 
Check dryer and drying 
hopper sizing. 
Bad dew point sensor. 
Replace. 
Poor dew point performance. 
Fouled dew point sensor 
manifold. 
Clear obstruction. Air should 
flow freely through sensor.