Dri-Eaz 1400 Manual Do Utilizador

Página de 12
 
07-01583B  06-07  Copyright 2007 Dri-Eaz Products, Inc. 
 
T
EST 
T
HERMOSTAT
:
 
1.  Move the system switch from OFF to the HEAT position. 
Press the button on the keypad until the setpoint 
temperature setting is a minimum of 3 degrees higher than 
the current room temperature. The EB1400 should start 
within several seconds. 
2.  The system switch in the OFF position. The EB1400 
should stop within several seconds on normal single stage 
heating or cooling systems. Note: On refrigeration 
systems you must wait 5 minutes for the automatic 
compressor short cycle protection period to expire, or 
press the RESET button to bypass this feature for initial 
testing purposes. Pressing the RESET button will erase 
any user program settings. 
3.  Place the system switch in the COOL position. 
4. Press 
the 
v button on the keypad until the setpoint 
temperature is a minimum of 3 degrees lower than the 
current room temperature. The cooling system should start 
within several seconds. 
 
5.  Place the fan switch in the AUTO position when using the 
EB1400. 
V
IEWING 
S
ET 
T
EMPERATURE
 
1.  Press and hold ^ or v button. The current setpoint 
temperature will be displayed in the place of the current 
room temperature, and the indicator SET will be displayed. 
2.  The display will return to normal operating mode when the 
^ or v buttons are released. The SET indicator will turn off, 
indicating that the current temperature shown in the 
display is the room temperature. Continuing to hold the ^ 
or v button for 3 seconds or longer will allow the user to 
change the current setpoint temperature (See Changing 
Set Temperature, below). 
C
HANGING SET 
T
EMPERATURE
 
1.  Press and hold ^ or v button for 3 seconds. The entire 
display will flash once and the SET indicator will be 
flashing. Release the ^ or v button and press the ^ or v 
button again as desired to adjust the set temperature. 
2.  The display will return to normal operating mode after 5 
seconds. 
3.  The SET indicator will turn off in the display, indicating that 
the current temperature shown in the display is the room 
temperature. 
H
IGH 
T
EMPERATURE 
S
AFETY 
S
WITCH
 
When the selector switch is set to HEAT, a software feature 
automatically turns the unit off if the room temperature rises 
above 93°F (34°C). If the temperature rises above 99°F 
(37°C), the thermostat mechanically turns the unit off.  
N
ON
-V
OLATILE 
M
EMORY
 
In the event of a power failure, the non-volatile memory feature 
of this unit allows all settings to be recovered. When AC power 
is restored after an outage, all settings are retrieved from 
memory and reinstated. 
 
 
R
ESETTING 
T
HERMOSTAT
 
The Reset feature allows the user to completely reset the 
thermostat to return to factory-set software settings. 
1. To erase all entered settings, gently press RESET button 
using a paper clip or a small pencil tip. 
2. This will return all thermostat settings to their default values 
and register all new manual switch settings for proper 
operation.  
 
D
UCTING 
I
NSTRUCTIONS FOR THE 
EB1400: 
D
UCT 
A:
 
H
EAT 
I
NLET
 
D
UCT 
B:
 
H
EAT 
O
UTLET
 
D
UCT 
D:
 
C
OLD 
O
UTLET
 
 
• 
D
UCTING
: The unit is ductable for directing 
conditioned air or heat into specific spaces. 
• 
D
UCTING 
S
IZE
: Use 8-inch diamater ducting and 
secure with clamps on duct adapters. 
• 
S
IDE 
D
UCTING
: When using duct on the side, 
ducting should be run sideways out doors and 
windows. Put unit in corner and duct up at an 
angle into ceiling tiles (not directly up). 
• 
R
IGID 
D
UCTING
:
 
 Duct A requires rigid ducting (not  
layflat) attached by clamps. 
 
A
PPLICATIONS 
(Visit the EB1400 VTC at):  
http://www.dri-eaz.com/VTC/EB1400.html
 
• 
C
OOLING 
I
MMEDIATE 
A
REA
: Cold air blowing from 
Duct D (not ducted) will cool overall room.  
• 
H
EATING 
A
REA
:
 
Duct B outputs heat; ducting is 
needed if ducting warm air outside room or to 
focus heat in targeted area. If not ducted outside 
the room then it will heat the immediate space.  
• 
N
EUTRAL 
A
IR 
C
ONDITIONING
: For neutral air 
conditioning duct both B (heat outlet) & A (heat 
inlet) outside the structure. 
• 
D
EHUMIDIFYING
:
 
Spot cool with dehumidification by 
ducting outlet D. No ducting is needed to 
dehumidify overall area.  
• 
S
POT 
C
OOLING
: For spot cooling point outlet D air 
stream to specific area or duct it to spot cool. 
 
T
RANSPORTING AND 
S
TORING
 
1.  Before transporting, move Duct B ducting adapter to either 
the front or back of the unit to prevent damage. Note: Do 
not expose the thermostat to moisture and rain when 
transporting in uncovered vehicles such as flatbed trucks. 
2.  Transport the unit on stairs or over rough surfaces upright 
on the Unimover or hand truck and hold in place using 
straps. WARNING! Take care when loading the unit on a 
hand truck; the unit could tip over resulting in personal