Lifebreath 195ECM Folheto

Página de 1
Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________
49 "
(1245)
STALE AIR
TO OUTSIDE
FRESH AIR
TO INSIDE
14 3/4"
(375)
19" (483)
Por ts 
7" (178 mm)
CONDENSATE 
DRAINS
BLOWERS
*NOTE: 
Front clearance of 25 inches (635 mm) 
 is recommended for ser vicing unit. 
MOTOR
FRESH AIR
FROM OUTSIDE
STALE AIR
FROM INSIDE
FILTER
 DEFROST
DAMPER
DEFROST AIR
FROM INSIDE
FILTER
Por ts 
6" (150 mm)
METAL CLASPS
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams. The two
cores are arranged for highly efficient counter current airflow.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common ECM motor. 5 speed
fan operation. 120 VAC, 1.4 Amps.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of case designed to accept four reinforced polyester
straps that are supplied with the unit.
DEFROST
Damper defrost system.
DEHUMIDISTAT
Adjustable Internal Dehumidistat.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance.
Insulated to prevent exterior condensation. Drain connections 2 - 1/2" (12 mm) OD.
CONTROLS
ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode (each mode has 5 speeds).
Control pad can be removed from HRV and remotely mounted.
Weight  106 lbs. (48 kg) Shipping Weight  108 lbs. (49 kg)
All units conform to 
CSA and UL standards.
Model 195ECM
DIMENSIONS 195ECM  
inches (mm)
*Sensible Efficiency – thermal   **Latent Efficiency – moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs
Performance
Net supply air flow in cfm (L/s) against external static pressure
E.S.P 
(external static pressure)
[cfm (L/s)]
@ 0.1" (25 Pa)
171 (81)
@ 0.2" (50 Pa)
164 (77)
@ 0.3" (75 Pa)
156 (74)
@ 0.4" (100 Pa)
143 (67)
@ 0.5" (125 Pa)
134 (63)
@ 0.6" (150 Pa)
126 (59)
@ 0.7" (175 Pa)
119 (56)
Max. Temperature Recovery
88%
Sensible Effectiveness
@ 114 cfm (54 L/s)
32°F (0°C)
88%
*Sensible Efficiency
@ 114 cfm (54 L/s)
32°F (0°C)
81%
*Sensible Efficiency
@ 119 cfm (56 L/s)
-13°F (-25°C)
77%
VAC @ 60HZ
120
WATTS / Low speed
34
WATTS / High speed
95
Amp rating
1.4
20
40
60
80
100
120
140
160
180
200
220
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
Static Pressure (in w.g.)
A
ir
 F
lo
w (
cf
m
)
OPTIONAL MAIN CONTROLS
99-350
Lifestyle Ventilation Control 7/24 programmable ventilation, (3 wire) 20
gauge wire (min.) 100’ length
99-109
Air Sentry Air Quality Monitor designed to accept remotely mounted
Control Pad, (3 wire) 20 gauge wire (min.) 100’ length
99-250
Ventilation Dehumidistat designed to accept remotely mounted Control
Pad, (4 wire) 20 gauge wire (min.) 100’ length
OPTIONAL TIMERS
99-104
Digital Electronic Timer - initiates high speed ventilation for 20, 40 or 60
minutes, (3 wire) 20 gauge wire (min.) 100’ length
99-101
Crank Timer - Initiates high speed ventilation for up to 60 minutes, (2 wire)
20 gauge wire (min.) 100’ length
OPTIONAL ACCESSORIES
99-163
Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 6” (150 mm)
99-164
Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 6” (150 mm)
99-185
Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6 mm) mesh screen
WARRANTY 
Units carry a LIFETIME warranty on the heat recovery core and a 5 year replacement
parts warranty.
The  ECM  motor  produces  a  tone  that  some  may 
find 
objectionable.  We 
recommend 
the 
installation of the optional 99-SILENCER6 on the 
‘Stale  Air  from  Inside’  and ‘Fresh  Air  to  Inside’ 
ducts. 
ATTENTION
TI-195ECM