Lifebreath 200ERVD Manual Do Utilizador

Página de 32
2
Table of Contents
Introduction................................................................... 2
Warranty ....................................................................... 2
ERV Questions & Answers .......................................... 3 
Climate Map ................................................................. 4
Technical Data - 
Model 95MAX 
................................... 5
Technical Data - 
Model 155MAX 
................................. 6
Technical Data - 
Model 200MAX 
................................. 7
Technical Data - 
Model MAXTOP
................................ 8
Technical Data - 
Model 195DCS 
................................. 9
Technical Data - 
Model 300DCS 
............................... 10
Technical Data - 
Model 200ERV 
................................ 11
Technical Data - 
Model 200ERVD 
............................. 12
Function and Control
Operation of the ControlAir 15 ....................................13
Glossary of Terms ......................................................13
To Select Mode of Operation.......................................14
Optional Remote Controls ......................................... 15
Using the Dehumidistat............................................ 16 
Schematic Diagram - 
Model 95MAX
....................... 17
m
Installation
Installation
............................................................... 18
• Location
• Mounting the HRV/ERV
• Electrical
• Installing the Drain Line and "P" Trap
Installing Air Ducts
.................................................. 19
• Outside Weatherhoods
• Locating the Weatherhoods
• Installing Ducting from Weatherhoods to the HRV/ERV
• Warmside Ducting 
Supply Air Ducting ..................................................... 20
Stale Air Exhaust System .......................................... 20
Dampers and Grilles .................................................. 20
Installation Diagrams .......................................... 21 - 24
Air Flow Balancing ..................................................... 25
Maintenance
Maintenance Routine For 
HRV
.................................. 27
Maintenance Routine For 
ERV
.................................. 28
Troubleshooting.......................................................... 29
Wiring Diagram .......................................................... 31
INTRODUCTION
HRV - Aluminum Core
A Heat Recovery Ventilator (HRV) is designed to
provide fresh air into a building while exhausting an
equal amount of stale air.  During the winter
months, the incoming cold fresh air is warmed by
utilizing the heat recovered from the stale air
before it is exhausted to the outdoors.  During
summer months when the indoor space is air 
conditioned, the Heat Recovery Ventilator will help
in cooling the incoming fresh air with the stale air
that is being exhausted.
ERV - Enthalpic Paper Core
An Energy Recovery Ventilator (ERV) is designed
to provide fresh air into a building while exhausting
an equal amount of stale air.  An ERV is designed
for use in warm humid areas with heavy air 
conditioning use.  The ERV will transfer both 
sensible and latent heat from the incoming fresh air
to the outgoing stale air thereby reducing the load
(due to ventilation) on the air conditioning system. 
ERVs are not suitable for climates where the 
temperature drops below -4˚C (25˚F).
WARRANTY
All Heat Recovery Ventilators carry a Lifetime
Warranty on the heat recovery core and a 5 (five)
year replacement parts warranty.
All Energy Recovery Ventilators carry a 5 (five) year 
warranty on the energy recovery core and a 5 (five)
year replacement parts warranty.
During the warranty period, if any core experiences a 
failure or perforation caused by normal use while
owned by the original purchaser,  a replacement core
(FOB our plant) will be supplied at no expense.
®