95 MAX Port Specifications
The 95 Max Heat Recovery Ventilator (HRV) has been
designed to allow the installer to choose between two
possible positions on the cabinet for the INDOOR
EXHAUST (return from building) port.  Illustrations in this
manual show standard (side mounted) port location . The
same specifications apply to both 95 Max setups, 
regardless of which port position is selected.
Variable Port Location / Installation (Model 95 Max only)
The 
exhaust return
port collar is not factory installed.
Installer may choose either 
side mounted
or alternate 
top
mounted
port by simply removing one of the two knock-out
plates and attaching a port collar (supplied). To remove
knock-out plate, insert a utility knife into the knock-out 
slits and trace them completely to puncture protective film
underneath. Then, cut the solid tabs between the slits, using
tin snips or side cutters, and remove the knock-out plate. If
any protective film still blocks the opening, 
remove it now
.
In order to make the 95 Max as space efficient as 
possible, the INDOOR supply and return ports are 
converted from round to oval shape. Overall size of the
port remains the same. Simply bend a standard duct 
fitting to the correct shape, and attach to the oval port
using the same method as for a round port.
95 MAX Air Flow
Stale air enters the FRONT RIGHT side port. The air will
pass down the front half of the core, then up the back half
of the core and out the RIGHT REAR port.
Fresh outdoor air will enter the LEFT REAR port and
pass down the back half of the core. It will then pass up
the front half of the core, and out the LEFT FRONT port.
This unique configuration allows the air to actually travel
through the core twice, making the 95 MAX almost as
efficient as a double core unit.
Removably 
Heat Recovery 
Core
Drain Pan
Drain spout
FRONT
TOP
knockout for
side mounting of
EXHAUST return  port
6" round collar
converted to oval
minimum
18 inches (459 mm)
required for
service access
Threaded
inserts (4)
at corners
SUPPLY
Fresh air
from outside
5" round collar
SUPPLY
Fresh air
to building
6" round 
(conv. to oval)
collar
EXHAUST
Stale Air
to outside
5" round collar
EXHAUST
Return air
from building
Choice of port location
Knockouts on top and
side of unit (use 1 only)
6" round (conv. to oval)
collar supplied
 DIMENSIONS 95MAX 
 
inches (mm)
18.5"
(470 mm)
18.5"
(470 mm)
16"
(406 mm)
SIDE
Hanging
straps (4)
24.5"
(622 mm)
HEAT RECOVERY VENTILATORS (HRVs)
¤
HEAT RECOVERY VENTILATORS (HRVs)
¤
Same Circumference
(6 inch)
diameter
Variable Port Location
SIDE MOUNTED PORT               TOP MOUNTED PORT
standard location                       alternate location
Round port bent to oval