UV LAMP CASING
Clip
UV Lamp  
Bulb Holder
Base of T300  
Air Purifier
Wire Harness 
(screw)
T300 REPLACING THE UV BULB
Replacing the UV Bulb
1)   Before replacing the UV bulb, please unplug the unit.
)   Lay the unit on its side and remove the screws of the UV bulb casing cover at the  
 
base of the unit.
3)  Unscrew the screw from the wire harness.
4)   Use one or two flat tip screw drivers to push outward the CLIP on the UV lamp  
 
bulb holder. If unable to use two flat tip screw drivers at the same time, hold the  
 
UV lamp bulb holder and push the clip outward one at a time but do not let the  
 
CLIP move back in when you are pushing the other clip outward.
5)  Take out the UV lamp bulb but do not touch the bulb when replacing the new one.
6)   Push the UV bulb holder back into the unit and secure the wire harness screw  
 
and the secure the base to the unit with the screws.