ZyXEL Communications 3110 Manual Do Utilizador
Chapter 2 SHD1110 Programming
Z-Wave Series Programming Guide
10
When the SHD1110 is triggered, it will send out BASIC_SET_COMMAND to the nodes of Grouping
2.
2.
Refer to the
section to configuration parameter 1 for the setting of basic set
command.
2.1.3 Z-Wave’s Configuration
The table below lists the configuration parameters and the value range for users to set up the
SHD1110.
SHD1110.
[Command Class Basic, Basic Set, Value = (255)0xFF]
send trigger-ON command
[Command Class Basic, Basic Set, Value = 0(0x00)]
send trigger-OFF command
Table 1
Z-Wave Configuration Table
PARAMETER
FUNCTION
SIZE (BYTE)
VALUE
UNIT
FACTORY
DEFAULT
DESCRIPTION
1
Basic Set
Level
Level
1
0~99
% of
Brightness
(Dimmer
Level)
99 / 99
Set basic set value to
be on (or Dim Level)
/off.
be on (or Dim Level)
/off.
0: Disable
2
Temperature
Trigger-ON
Value
Trigger-ON
Value
1
-20~50
or
99
Degree
30 / 99
Set temp.trigger-ON
value to be _ degree.
value to be _ degree.
99: Clear Temp.
trigger-ON value
trigger-ON value
3
Temperature
Trigger-OFF
Value
Trigger-OFF
Value
1
-20~50
or
99
Degree
20 / 99
Set temp.trigger-OFF
value to be _ degree.
value to be _ degree.
99: Clear Temp.
trigger-OFF value
trigger-OFF value
4
Humidity
Trigger-ON
Value
Trigger-ON
Value
1
20~90
or
99
%
50 / 99
Set humid. trigger-
ON value to be _%.
ON value to be _%.
99: Clear Humid.
trigger-ON value
trigger-ON value
5
Humidity
Triger-OFF
Value
Triger-OFF
Value
1
20~90
or
99
%
40 / 99
Set humid. trigger-
OFF value to be _%.
OFF value to be _%.
99: Clear Humid.
trigger-OFF value
trigger-OFF value
6
Auto Report
(Time
Interval)
(Time
Interval)
2
1~1439
or
99
Minute
0 / 0
Set auto report time
interval to be _ mins.
interval to be _ mins.
0: Disable auto
report
report