Vanguard Heating NLFB32NC Manual Do Utilizador

Página de 24
www.desatech.com
105604-01H
8
AIR FOR COMBUSTION 
AND VENTILATION
Continued 
VENTILATION AIR
Ventilation Air From Inside Building 
This fresh air would come from an adjoining un-
confined space. When ventilating to an adjoining 
unconfined space, you must provide two perma-
nent openings: one within 12" of the ceiling and 
one within 12" of the floor on the wall connecting 
the two spaces (see options 1 and 2, Figure 4). You 
can also remove door into adjoining room (see 
option 3, Figure 4). Follow the National Fuel Gas 
Code ANSI Z223.1/NFPA 54, Section 5.3, Air for 
Combustion and Ventilation for required size of 
ventilation grills or ducts. 
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or 
ducts. You must provide two permanent openings: 
one within 12" of the ceiling and one within 12" 
of the floor. Connect these items directly to the 
outdoors or spaces open to the outdoors. These 
spaces include attics and crawl spaces. Follow the 
National Fuel Gas Code ANSI Z223.1/NFPA 54, 
Section 5.3, Air for Combustion and Ventilation for 
required size of ventilation grills or ducts.
Figure 4 - Ventilation Air from Inside 
Building
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Grills 
Into Adjoining Room,
Option 2
Ventilation
Grills 
Into Adjoining 
Room,
Option 1
12"
12"
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
Figure 5 - Ventilation Air from Outdoors
IMPORTANT:
 Do not provide openings for inlet 
or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic 
will activate the power vent.
INSTALLATION
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice person must install firebox. 
Follow all local codes.
 WARNING: Never install the 
firebox
•  in a bedroom or bathroom
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing,  or  other  flammable 
objects are less than 42 inches 
from the front, top, or sides of 
the firebox
•  in high traffic areas
•  in windy or drafty areas
 WARNING: Never install the 
firebox
•  in a bedroom or bathroom
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing,  or  other  flammable 
objects are less than 42 inches 
from the front, top, or sides of 
the firebox
•  in high traffic areas
•  in windy or drafty areas