Vanguard Heating VSGF-28NTE Manual Do Utilizador

Página de 32
www.desatech.com
113135-01C
8
 WARNING: Never install the 
fireplace
•  in a bedroom or bathroom
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing,  or  other  flammable 
objects are less than 42 inches 
from the front, top, or sides of 
the fireplace
•  in high traffic areas
•  in windy or drafty areas
 WARNING: These models have 
a three-prong, grounded electrical 
plug. This plug helps protect you 
against electrical shock. Only con-
nect plug to a properly grounded, 
three-prong receptacle. Do not cut 
or  remove  the  grounding  prong 
from this plug.
 CAUTION: This fireplace cre-
ates  warm  air  currents.  These 
currents move heat to wall sur-
faces next to fireplace. Installing 
fireplace  next  to  vinyl  or  cloth 
wall  coverings  or  operating 
heater  where  impurities  (such 
as,  but  not  limited  to,  tobacco 
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps, 
etc.) in the air exist, may discolor 
walls or cause odors.
Note: 
Your fireplace is designed to be used in zero 
clearance installations. Wall or framing material 
can be placed directly against any exterior surface 
on the rear, sides, or top of your fireplace, except 
where standoff spacers are integrally attached. If 
standoff spacers are attached to your fireplace, 
these spacers can be placed directly against wall 
or framing materials.
Use the dimensions shown for rough openings to 
create the easiest installation (see Built-In Fire-
place Installation, page 11).
AIR FOR COMBUSTION 
AND VENTILATION
Continued
INSTALLATION
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
 WARNING: A qualified ser-
vice  person  must  install  fire-
place. Follow all local codes.
Figure 4 - Ventilation Air from Outdoors
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or 
ducts. You must provide two permanent openings: 
one within 12" of the ceiling and one within 12" 
of the floor. Connect these items directly to the 
outdoors or spaces open to the outdoors. These 
spaces include attics and crawl spaces. Follow the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54, 
Section 5.3, Air for Combustion and Ventilation for 
required size of ventilation grills or ducts. 
IMPORTANT:
 Do not provide openings for inlet 
or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic 
will activate the power vent.