Installation Procedure 
Positioning the Heater 
 
NOTE:   It  is not necessary to direct connect this  unit  unless installed in improper drawing 
fireplace or oversized flue.  It is recommended a chimney connector be installed from the 
appliance flue collar to the first fireplace chimney section. 
WARNING
    
 
WHEN  POSITIONING  THE HEATER, THE FOLLOWING CONDITIONS  MUST  BE MET! 
 
1.  The front of the damper opening must be positioned BEHIND the rear edge of the lintel to 
ensure proper draft. 
2.  Center the heater in the fireplace opening. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Mounting the Trim Panels
 
After  the unit is positioned, mark the mounting position of  the trim panels as follows: 
1.  Set the side trim panels in place,  flat against the face  of the  fireplace.  Mark down the 
inside edge of the trim  panel  to make a vertical reference line. 
2.  Set the top (long) trim panel in place on top of  the  unit.  The  panel should be flat against 
the outside face of  the  fireplace, and standing vertically.  Mark along the lower edge of the 
trim panel with a pencil to make a reference line for mounting. 
3.  Slide the unit out of the fireplace far enough to work behind the trim panel reference lines. 
4.  Mount the side trim panels. (See Figure 2.)  
     a. Position the trim panel on the reference line. 
     b. Drill mounting holes in center of trim panel mounting brackets to allow for adjustment in 
         and out if necessary. 
     c. Mount the trim panel using the self-tapping screws provided. 
5.  Place top panel back on reference mark.  Take top trim panel mounting bracket supplied 
with unit.  Position bracket so it overlaps rear lip of top trim panel.  Drill mounting holes in 
top of stove using holes in bracket as guide.  Tighten down screws. 
6.  Now, follow the installation procedures in the listed direct connect or positive connect kit 
you are using and install the heater and connect kit in the fireplace.  