 P42-4 Zero Clearance Direct Vent Gas Fireplace
11
6-7/8"
(173mm) dia.
Flue pipe
4" (102mm)
dia. flue pipe
Termination Cap
Part #946-523/P
AstroCap
spring
spacer
Wall Thimble (2 pc)
INSTALLATION
VENTING
Regency
®
 Direct  Vent System (Flex) Horizontal Terminations Only
These venting systems, in combination with the P42 Direct Vent Gas 
Fireplace, have been tested and listed as a direct vent heater system 
by Warnock Hersey. The location of the termination cap must conform to 
the requirements in the Vent Terminal Locations diagram in the "Exterior 
Vent Termination Locations" section. 
Regency
®
 Direct Vent (Flex) System Termination Kit (Part # 946-515) 
includes all the parts needed to install the P42 with a maximum 
run of 4 feet.
1)  6-7/8" dia. fl exible liner (4 ft. length)
2)  4" dia. fl exible liner (4 ft. length)
3)  spring spacers (4)
4) thimble 
(2)
5)  AstroCap termination cap (1)
6) screws 
(12)
7)  tube of Mill Pac (1)
8) plated 
screws 
(8)
9)  screws #8 x 1/2" Drill Point, stainless steel (4)
If longer runs are needed, the Regency
®
 Direct Vent system (Flex) 
# 946-516 includes all the parts needed to install the P42 with a 
maximum 10' run.
1)  6-7/8" dia. fl exible liner (10 ft. length)
2)  4" dia. fl exible liner (10 ft. length)
3)  spring spacers (7)
4) thimble 
(2)
5)  AstroCap termination cap (1)
6) screws 
(12)
7)  tube of Mill Pac (1)
8) plated 
screws 
(8)
9)  screws #8 x 1/2" Drill Point, stainless steel  (4)
Note: 
a)  Liner sections should be continuous without any joints or seams.
b)  Only Flex pipe purchased from Regency
®
 may be used for Flex 
Installations.