INSTALLATION
UNIT SPECIFICATIONS
This includes:
1)  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label 35,000 Btu/h) 
after burning appliance for 15 minutes.
2)  If required, adjusting the primary air to 
ensure that the fl ame does not carbon. 
 
First allow the unit to burn for 15-20 min. 
to stabilize.
CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.
MANUFACTURED 
MOBILE HOME 
ADDITIONAL 
REQUIREMENTS
1)  Ensure that structural members are not cut 
or weakened during installation.
2)  Ensure proper grounding using the #8 
ground lug provided. See the "Wiring 
Diagram" section.
LOCATING YOUR 
GAS FIREPLACE
1)  When selecting a location for your stove, 
ensure that the clearances outlined on this 
page are met.
2)  P r o v i d e   a d e q u a t e   c l e a r a n c e s   f o r 
servicing.
3)  The appliance must be installed on a fl at, 
solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or raised up 
on a platform to enhance its visual impact. 
If the appliance is going to be installed 
on carpeting, combustible linoleum tile or 
other combustible material other than wood 
fl ooring, the appliance must be installed on a 
metal or wood panel extending the full width 
and depth of the appliance.
4)  The P42 Direct Vent Gas Fireplace can be 
installed in a recessed position or framed out 
into the room as in A, B, C, D. See Diagram 
1.
HEARTH
A hearth is not mandatory, but is recommended 
for aesthetics and for added safety.
5)  This appliance is Listed for bedroom 
 
installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
6)  The P42 Direct Vent Gas Fireplace is 
approved for alcove installations, which 
meet the clearances listed on this page.
7)  We recommend that you plan your installation 
on paper using exact measurements for 
clearances and fl oor protection before 
actually installing this appliance. Have an 
authorized inspector, dealer, or installer 
review your plans before installation.
Note: For vent terminations see the 
"Exterior Vent Termination Locations" 
section.
HEATWAVE 
OPTIONAL DUCT 
SYSTEM  KIT 
#946-556
The  HeatWave Air Duct Kit increases the 
effectiveness of your fi replace by dispersing 
warm air from the fi replace to remote locations in 
the same room or other rooms in your home. 
Up to  two kits may be installed on the fi replace. 
Please Note: Only 1 HeatWave kit may be 
operated at one time. This includes the internal  
blower option as well. 
A) Flat 
on 
Wall
B) Flat 
on 
Wall 
Corner
C) Recessed 
into 
 Wall/Alcove
D) Corner
OPTIONAL 
HEAT RELEASE KIT
#946-570
The Heat  Release Kit expels warm air from 
the fi replace to the outside of the building, 
allowing the fi replace to be operated with less 
heat entering the room. The kit may be used on 
either the left or right side.