OPERATING INSTRUCTIONS
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the 
appliance with the glass removed.
5)  Verify that the venting and cap are 
unobstructed.
6)  Ensure that the brick panels are installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
IMPORTANT Gas on/off knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.
Ensure that the 3 way switch on the manual 
control panel is in the "Remote" position.
1)  Push in gas control knob slightly and turn 
clockwise to “OFF”. Knob cannot be turned 
from “PILOT” to “OFF” unless knob is pushed 
in slightly.  Do not force.
2)  Wait fi ve (5) minutes  to clear out any gas. 
3)  Turn knob  on gas control counterclockwise        
to “PILOT”.
4)  Push in control knob all the way and hold  in 
until the pilot lights up. Continue to hold the 
control knob in for about 20 seconds after 
the pilot is lit. Release knob and it will pop 
back up. Pilot should remain lit. If it goes out, 
repeat steps 1) to 4).  If knob does not pop 
up when released, stop and immediately 
call your service technician or gas supplier. 
If the pilot will not stay lit after several tries, 
turn the gas control knob to “OFF” and call 
your service technician or gas supplier.
5)  Turn gas control knob counterclock-wise to 
“ON”.
6)  Turn the unit on. 
 
NOTE: If using the remote control refer to 
the FireWizard manual for instructions.
SHUTDOWN 
PROCEDURE
1)  Press the ON/OFF switch once.
2) The 
LED 
will 
fl 
ash.
3)  Turn the main gas control clockwise to the 
"OFF" position to turn off the pilot.
4)  Turn off all electric power to appliance if 
service is to be performed.
During the fi rst  few  fi res, a white fi lm 
may develop on the glass front as part of 
the curing process. The glass should be 
cleaned after the unit has cooled down 
or the fi lm will bake on and become very 
diffi cult to remove. Use a non-abrasive 
cleaner and DO NOT ATTEMPT TO CLEAN 
THE GLASS WHILE IT IS HOT.
Only when the pilot holds, without pressure 
being applied to the control knob, reapply the 
tension springs to the door. The unit must 
not
 be operated with the tension springs 
unattached. 
IMPORTANT
To ignite or reignite the pilot, 
you must fi rst release the 
tension springs below the door. 
LIGHTING 
PROCEDURE
The  FIRST FIRE in your heater is part of the 
paint curing process. To ensure that the paint 
is properly cured, it is recommended that you 
burn your fi replace for at least four (4) hours the 
fi rst time you use it with the fan on. 
When fi rst operated, the unit will release an 
odour caused by the curing of the paint and the 
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off 
at this time. Open a few windows to ventilate 
the room for a couple of hours. The glass may 
require cleaning.
NOTE:  The main burner will always start on 
"HIGH" and resume it's last setting after 
20 seconds of operation.
NOTE: When the glass is cold and the appliance 
is lit, it may cause condensation and fog 
the glass. This condensation is normal 
and will disappear in a few minutes as 
the glass heats up.
DO NOT ATTEMPT TO CLEAN THE 
GLASS WHILE IT IS STILL HOT
!
FIRST FIRE
DO NOT BURN THE APPLIANCE 
WITHOUT THE GLASS FRONT IN 
PLACE.