 L900-1 Direct Vent Gas Fireplace
27
INST
ALLA
TION
WIRING DIAGRAM 
AERATION ADJUSTMENT
The burner aeration is factory set but may need 
adjusting due to either the local gas supply or 
altitude. Open the air shutter for a blue fl ame or 
close for a more yellow fl ame. 
In order to adjust the aeration, the logs, grate 
and burner will need to be removed to be able 
to access the shutters.
Minimum Air Shutter Opening:
NG     1/8"
LP     1/2"
CAUTION: Label all wires prior to disconnection 
when servicing controls. Wiring errors can 
cause improper and dangerous operation.
Caution: Ensure that the wires do not touch any 
hot surfaces and are away from sharp edges.
CAUTION:  Carbon will be produced if air shutter 
is tightly closed.
Note:   Any damage due to carboning 
resulting from improperly setting 
the aeration controls is NOT covered 
under warranty.
INSTALLATION
NOTE: The #8 ground lug is located on 
the outer left side of the unit.