FLUEING
INTRODUCTION
The  P121/P121LC/P121RC/P131  uses  the
"balanced  flue"  technology Co Axial system.
The inner liner flue products of combustion to
the outside while the outer liner draws outside
combustion air into the combustion chamber
thereby eliminating the need to use heated room
air for combustion and losing warm room air up
the chimney.
Note: These flue pipes must not be con-
nected  to  any  other  appliance.
The  gas  appliance  and  flue  system  must  be
flueed directly to the outside of the building, and
never  be  attached  to  a  chimney  serving  a
separate solid fuel or gas burning appliance.
Each  direct  flue  gas  appliance  must  use  it's
own separate flue system. Common flue sys-
tems are prohibited.
INSTALLATION
UNIT  ASSEMBLY
PRIOR TO
INSTALLATION
The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped
into position.
Top Standoff Assembly
The top standoffs are shipped in a flat position and must be folded into shape and attached.
1) Remove  the  standoffs  from  the  fireplace
top.
2) Take  each  standoff  and  bend  into  the
correct shape. Bend up at the bend lines
until the screw holes in the standoff and the
pre-punched screw holes on the fireplace
top line up.
3) Attach the standoff securely to the top with
4  screws  per  standoff  (on  opposite  cor-
ners).
FACING & FINISHING REQUIREMENTS
This fireplace is supplied with a 3" metal extension trim above the fireplace. The extension trim may be replaced if the framing is faced with a non-
combustible material placed flush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.)