Regency P121-NG Manual Do Utilizador

Página de 40
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
32
12) Lift the entire assembly out.
8) Remove  the Side Base Brick Panels and
finally the Long Base Brick Panels.
MAINTENANCE
Remove Left & Right  Side Base
Brick  Panels
Remove the 2 Long Base Brick Panels
9) Disconnect the inlet gas line.
10) Disconnect  the  2  TP  wires  and  the  2  TH
wires  from  the  valve.
11) Remove the 16 Phillips head screws secur-
ing the valve tray.
13) Undo the pilot tube from the valve with a
7/16"  spanner.
14) Undo the quick drop out thermocouple nut
on the valve with a 9mm (metric) spanner.
15) Remove  the  Piezo  igniter  wire  and  push
button  assembly.
16) Undo the "gas out" flare nut with a 13/16"
spanner.
17) Undo  the  "gas  out"  flare  fitting  with  an
11/16"  spanner.
18) Remove the 6 Phillips head screws from the
sides  of  the  valve  bracket  and  remove
valve.
Hint:
If you are using black pipe, ensure
that there is a union by the valve,
otherwise  removal  will  be  almost
impossible.
INSTALLING  VALVE
1) Attach the valve to the valve bracket with
the  6  (m5x8  metric)  screws  provided.
2) Reconnect the "gas out" flare fitting with an
11/16"  spanner.
3) Reconnect the "gas out" flare nut with a 13/
16"  spanner.
4) Install piezo ignitor push button assembly
and  reconnect  wire.
5) Reconnect the quick drop out thermocouple
nut with a 9mm spanner.
6) Reconnect the pilot tube nut with a 7/16"
spanner.
7Scrape off the old gasket from the floor of
the firebox and from the valve tray assem-
bly.
8) Install a new gasket and reinstall the valve
tray  assembly.
Note:  Failure  to  install  a  new  gasket  may
severely  affect  the  appliance  perform-
ance.
9) Reinstall  the  16  hold  down  screws.
10) Hook up the 2 TP and 2 TH wires to the
appropriate connections on the valve.
11) Reinstall the Burner Assembly.
13) Hook up the gas line and check for gas leaks
with a soap and water solution or a gas leak
detector. (Do not use open flame for leak
testing.)
14) Fire up the unit temporarily
15) Check the manifold pressure.
16) Reinstall the logs, grate  and brick panels as
needed.
17) Reinstall the glass doors.
18) Fire up the unit again and check for proper
flame  appearance.