Regency P121 Manual Do Utilizador

Página de 48
Regency
®
 P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace
34
LIGHTING 
PROCEDURE
NOTE: For all propane units and units    
equipped with electric spark boxes, 
see "Copy of Lighting Plate Instruc-
tions" section for more details.
Only when the pilot holds, without pressure 
being applied to the control knob, resecure the 
glass panel to the unit. The unit must not be 
operated with the glass removed. 
IMPORTANT Gas on/off knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.
1)  Turn burner OFF using "ON/OFF" switch.
2)  Turn gas control knob so indicator points 
to "OFF" position and allow 5 minutes for 
any gas in the combustion chamber to 
escape.
OPERATING INSTRUCTIONS
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the 
appliance with the glass removed.
5)  Verify that the venting and cap are 
unobstructed.
6)  Ensure that the brick panels are installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
3)  Turn gas control knob counterclockwise 
so indicator points to the "PILOT" position. 
Depress the gas control knob fully. Depress 
the igniter button several times until the 
pilot lights. After approximately one minute, 
release the gas control knob. The pilot fl ame 
should continue to burn. If the pilot does 
not remain lit, repeat operation allowing a 
longer period before releasing gas control 
knob.
4)  When the pilot stays lit, turn the gas knob 
further counterclockwise to the "ON" 
position.
5)  Use the wall switch, thermostat or remote 
control to turn on the unit.
6)  Rotate the fl ame height regulator to adjust 
the fl ame height higher or lower.
SHUTDOWN 
PROCEDURE
1)  Use the wall switch, thermostat or remote 
control to turn off the main burner.
2)  Turn the main gas control clockwise to the 
"OFF" position to turn off the pilot.
FIRST FIRE
DO NOT BURN THE APPLIANCE 
WITHOUT THE GLASS FRONT IN 
PLACE.
The fi rst fi re in your fi replace is part of the paint 
curing process. To ensure that the paint is 
properly cured, it is recommended that you burn 
your fi replace for at least four (4) hours the fi rst 
time before you use it with the fan on. 
When fi rst operated, the unit will release 
an odour caused by the curing of the paint, 
the burning off of any oils remaining from 
manufacturing. Smoke detectors in the house 
may go off at this time. Open a few windows to 
ventilate the room for a couple of hours. 
Note:  When the glass is cold and the 
appliance is lit, it may cause 
condensation and fog the glass. 
This condensation is normal and 
will disappear in a few minutes as 
the glass heats up.
AERATION 
ADJUSTMENT
The air shutter can be adjusted by moving the 
adjusting wire up or down. The wire is accessed 
through the bottom louver opening. Open the air 
shutter for a blue fl ame or close for a yellower 
fl ame. The burner aeration is factory set but 
may need adjusting due to either the local gas 
supply or altitude. 
Minimum Air Shutter Opening:
 3/16" 
Natural 
Gas
 3/8" 
Propane
CAUTION: Carbon will be produced if air shutter 
is closed too much. 
Note:   Any damage due to carboning 
resulting from improperly setting 
the aeration controls is NOT covered 
under warranty.
Closed - Tall yellow
Open - Short Blue
Note:  Aeration Adjustment should only be 
performed by an authorized Regency
®
 
Installer at the time of installation or 
service.
Adjustment Wire - Push to close or
pull to open aeration cap.
During the fi rst few fi res, a white fi lm may 
develop on the glass front as part of the 
curing process. The glass should be cleaned 
after the unit has cooled down or the fi lm 
will bake on and become very diffi cult to 
remove. Use a non-abrasive cleaner and 
DO NOT ATTEMPT TO CLEAN THE GLASS 
WHILE IT IS HOT.
IMPORTANT
To ignite or reignite the pilot, 
remove one glass panel/door.