 Regency E21 Gas Fireplace Insert
INSTALLATION 
POLICY FOR SOLID 
FUEL BURNING & 
FACTORY BUILT 
FIREPLACES
The Regency E21 may be installed and vented 
into any solid fuel fi replace that has been installed 
in accordance with the National, Provincial and 
local building codes and is constructed of non-
combustible materials. 
1)  Installer must mechanically attach the sup-
plied label to the inside of the fi rebox of the 
fi replace into which the gas fi replace insert 
is installed.
2)  Do  not  cut  any  sheet-metal  parts  of  the 
fi replace, in which the gas fi replace insert 
is to be installed.
3)  If the factory-built fi replace has no gas access 
hole(s) provided, an access hole of 1-1/2" 
(37.5mm) or less may be drilled though the 
lower sides or bottom of the fi rebox in a proper 
workmanship like manner. This access hole 
must  be  plugged  with  a  non-combustible 
insulation after the gas supply line has been 
installed.
4)  The fi replace fl ue damper can be fully blocked 
open or removed for installation of the gas 
fi replace insert.
5)  The fi replace and fi replace chimney must 
be  clean  and  in  good  working  order  and 
constructed of non-combustible materials.
6)  The chimney cleanouts must fi t properly.
7)  Refractory (fi rebricks), glass doors, screen 
rails, screen mesh and log grates can be 
removed from the fi replace before installing 
the gas fi replace insert.
8)  Smoke shelves, shields and baffl es may be 
removed if attached by mechanical fasteners. 
If any part is removed it must not weaken 
the structural integrity of the factory built.
9)  Trim  panels  or  surrounds  shall  not  seal 
ventilation openings in the fi replace.
MINIMUM FIREPLACE 
CLEARANCES
Diagram shows the minimum fi replace opening 
required to be able to install the Regency gas 
fi replace insert.
INSTALLATION 
CHECKLIST
1)  Locate  appliance,  check  Clearances  to 
Combustibles, page 7.
2)  Make gas and electrical connections, page  
8. Test the pilot. Must be as per diagram, 
page 11.
3)  Install Flue Connector, page 9.
4)  Install vent, page 10.
5)  Test  Gas  pressure,  page  10,  and  check 
aeration, page 11.
6)  Test for fl ue spillage, page 11.
7)  Install brick panels (optional), page 11.
8)  Install log set, page 11.
9)  Install Faceplate and Trim, page  12.
10) Install Flush Door Front (Standard), page 
13.
11) Install Optional Bay Front and optional Bay 
Gold Trim, page 14.
12) Install Louvers (Flush or Bay), pages 13 and 
14.
13) Install optional Wall Switch, Remote Control, 
or Wall Thermostat, page 19.
14) Final check, page 20.
Before  leaving  this  unit  with  the  customer, 
the installer must ensure that the appliance is 
fi ring correctly and operation fully explained to 
customer.
This includes:
1)  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.
3)  Ensure  that  the  appliance  is  venting 
correctly.
CAUTION:  Any alteration to the product that 
causes  sooting  or  carboning  that  results 
in damage is not the responsibility of the 
manufacturer.
Note: If you are installing the Molded Faceplate, 
the  minimum  fireplace  dimensions  are  as 
follows:
Width (at front):  29-1/8" (740mm)
Depth: 
15" (381mm)
Height: 
18-5/8" (473mm)
"
WARNING: This fi replace has been converted 
for  use  with  a  gas  fi replace  insert  only  and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."