Enviro 50-029 Manual Do Utilizador

Página de 33
Initial Installation
QUALIFIED INSTALLERS ONLY
H
ORIZONTAL
 I
NSTALLATION
:
STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are 
in the way when the venting system is attached. If this is the case, you may want to adjust the 
location of the appliance.
STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the 
desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented 
towards the wall or floor, as much out of view as possible.
Place  a  bead  of  Mil-Pac  on  the 
outer  edge  of  the  inner  exhaust 
pipe (non-flared end). Place a bead 
of  high  temperature  silicone  on  the 
male edge of the outer pipe. Push the 
pipe  sections  completely  together, 
then twist-lock one section clockwise 
approximately 1⁄4 turn, until the two 
sections are fully locked. The female 
locking lugs will not be visible from 
the outside, on black pipe. They may 
be located by examining the inside of 
the female ends as shown in Figure 
12.
Notes: 
(1) Twist-lock procedure: four (4) indentations, located on the female end of the pipes and fittings, are 
designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe 
indentations so they match and slide into the four entry slots on the male end.
(2) Horizontal runs of vent pipe must be supported every three feet. Wall straps are available for this 
purpose, also when running horizontal pipe minimum clearances to combustibles must be maintained; 
inches (5.1 cm) at top, 11⁄2 inches (3.8 cm) at sides, 11⁄2 inches (3.8 cm) at bottom.
Sealant
Female
Locking
Lugs
Male
Locking
Lugs
Figure 12: Twist-Lock Connection
Woodscrews
Wall Thimble
Strap
Sheet metal
screws
Fold strap
here
1
1
/
4
"
(3.2cm)
Figure 14: Installing Decorative Wall Thimble.
10"
(254mm)
10"
(254mm)
Figure 13: Wall Framing Hole for 
Horizontal Installation. 
14