Initial Installation
QUALIFIED INSTALLERS ONLY
F
REESTANDING
 D
RAFTHOOD
 A
DAPTOR
 - 50-841:
This Drafthood Adaptor is a complete assembly and is ready to fit onto your Westport in a vertical vent 
application only. With the Drafthood Adaptor correctly installed and wired to the gas control valve. Your 
Direct Vent Fireplace can be vented like a B-Vent Fireplace.
INSTALLATION:
WARNING:  
This Freestanding Drafthood Adaptor must be fitted by a qualified service technician.
1.  Remove the Drafthood Adaptor from the packaging. Ensure the unit and wire harness are undamaged. If 
there is damage contact your dealer, distributor, or courier company before starting this installation.
2. Install the adaptor so the wires exit to the rear of the fireplace. Slide the Drafthood Adaptor over the 
outlet pipe of the fireplace until the bottom of the adaptor collar stops on the top of the outlet. The 
Drafthood Adaptor must be safely secured to the vent flanges with either self-tapping screws and/or 
high temperature sealant.
WARNING: During the fitting of the Drafthood Adaptor, ensure that the wires are not pinched between 
the adaptor and the collar and/or flue outlet. Ensure that the opening of the Drafthood Adaptor is not 
blocked or obstructed.
3. Being careful not to run any wiring tight across metal edges; connect them to the valve and “ON/OFF” 
switch (refer to Figure 39).
Optional remote
control receiver
ON / OFF / Remote
thermostat switch
Purple
Grey
Blue
Grey
Grey
Optional
Thermostat
Optional
wall switch
Valve
Drafthood adaptor
300
o
F (149
o
C)
manual reset
temperature
sensor
Figure 39: Wiring Diagram for Electrical Connection.
4. Adjust  the  restrictor  plate 
to position 2.5 of 5. See the 
vent  restrictor  settings  in 
the instruction manual.
5. Adjust  the  embers  on  the 
burner  so  they  don’t  cover 
the burner ports.
WIRING DIAGRAM:
The  fireplace  connections 
are  labelled  in  Figure  39. 
When installing the Drafthood 
Adaptor onto a fireplace fitted 
with an optional wall switch or 
an optional thermostat, remove 
one  wire  from  the  switch  to 
the gas valve and connect the 
Drafthood Adaptor harness as 
shown in Figure 39.
GENERAL VENTING INFORMATION:
Canadian Installations
The venting system must be installed in accordance with the current CSA B149 installation code and/or 
local codes having jurisdiction.
U.S.A. Installations
The  venting  system  must  be  installed  in  accordance  with  the  current  National  Fuel  Gas  Code,  ANSI 
Z223.1, and/or local codes having jurisdiction.