Ultimate Products SA Manual Do Utilizador

Página de 58
 
2319 Laurelbrook Street, Raleigh, NC 27604 · (800) 542-7221 · FAX (919) 834-4526 · www.ultimate-products.com
  - 5 -
A.2 
PACKAGING AND SHIPPING INFORMATION (CONT.) 
            Options: 
Fresh air Intake (Mounted to Burner/Control) 
 
 
 
Fan Vent Adapters- Vertical and Horizontal 
 
 
 
Thermostat 
 
 
 
Flexible Gas Connector 
 
 
 
Ball Valve 
 
 
 
Vent Hoods 
 
 
 
Hanging Assembly (chain, etc.) 
 
 
Shipping packages for individual projects will be boxed and crated as outlined 
 
on the specific bill of lading. 
 
A.3 
MOUNTING CLEARANCES 
 
The heater should be positioned so that clearances from combustible materials  
will meet or exceed those shown in the following table. Also, ensure that there is 
at least  6” clearance on all sides of burner for service access and for free flow of 
combustion air. When heater is angle mounted, the burner/control assembly 
must remain horizontal. 
 
 
Minimum Clearances To Combustibles In  Inches 
Model 
Input – BTU / HR 
GH / ER / AL / SC 12 
40,000 
43 
20 
GH / ER / AL / SC 15 
50,000 
66 
20 
GH / ER / AL / SC 18 
60,000 
66 
20 
GH / ER / AL / SC 22 
75,000 
66 
20 
GH / ER / AL / SC 29 
100,000 
72 
30 
12 
GH / ER / AL / SC 38 
130,000 
72 
30 
12 
GH / ER / AL / SC 44 
150,000 
93 
36 
12