Troubleshooting
Follow these procedures in the order presented.
W A R N I N G
TURN OFF HEATER AND ALLOW TO COOL
COMPLETELY BEFORE SERVICING.
CONDITION
POSSIBLE CAUSE
SOLUTION
No spark at pilot when Ignitor is
operated.
1. Ignition Electrode is disconnected
from ignition wire, broken or
incorrectly positioned.
2. Ignitor wire is broken.
3. Bad Piezo Ignitor.
1. Inspect and re-connect, replace
or repair as necessary.
2. Replace wire.
3. Replace Piezo Ignitor.
The Ignitor Electrode sparks,
but Pilot does not light.
1. Gas supply is turned off or supply
line shut-off valve is closed.
2. Control Knob is not in PILOT
position.
3. Control Knob not pressed in while
in PILOT position.
4. Air present in gas lines.
5. Inlet supply pressure is not within
correct settings.
6. Other conditions that should be
identified only by a qualified gas
technician.
1. Turn on gas supply or open
supply line shut-off valve.
2. Turn Control Knob to PILOT.
3. Press Control Knob in while in
the PILOT position.
4. Continue holding in Control Knob
and repeat ignition procedure
until air is bled from the lines.
5. Call local gas supplier. Adjust
inlet supply pressure to specifica-
tion: NG; 5.5” w.c.-14.0”w.c. LP;
11.0” w.c.-14.0”w.c.
6. Call qualified gas technician.
PILOT
ON
OFF
PILOT
ADJ
LO
HI
TPTH
TH
TP
Piezo Ignitor
Regulator
Pilot / Main Control
HV104
Fig. 34  Honeywell valve assembly.