FMI V32S Manual Do Utilizador

Página de 24
www.fmiproducts.com
108662-01L
4
PRODUCT FEATURES
opeRAtIoN
This firebox is designed for use with approved 
ANSI Z21.11.2 decorative type unvented room 
heaters. (Physical size limitations apply. Refer 
to  minimum  firebox  requirements  supplied 
with log heater.) It requires no outside vent-
ing or chimney making installation easy and 
inexpensive. When used without the blower, 
the  firebox  requires  no  electricity  making  it 
ideal for emergency backup heat.
bloWeR AccessoRy
The circulating models will accept either a ro-
tary type fan (model BK) or the triple radial fan 
blower system (model BK3) accessories. The 
blower circulates heated air from the firebox 
into the room. Use of blower is optional.
ReFRActoRy bRIck lINeR 
Your firebox may feature a concrete refrac-
tory  brick  liner. As  with  all  concrete  liners, 
this  liner  may  develop  slight  cracks  when 
exposed to heat. These cracks will not affect 
the performance of the fireplace or vent-free 
gas logs.
outsIde AIR kIt AccessoRy
Fireboxes  that  include  “A”  in  their  model 
number can accept any AK4 series outside 
air kit accessory.
The optional AK4 air  kit provides  additional 
outdoor air to improve burner efficiency and 
reduce build-up of condensation in the living 
space. Follow the instructions included with 
the air kit.
LOCATINg FIREBOX
plANNING 
Plan where you will install the firebox. This will 
save time and money later when you install 
the firebox. Before installation, consider the 
following:
1.  Where the firebox will be located. Allow for 
wall and ceiling clearances (see Installa-
tion Clearances
, page 10).
2.  Everything needed to complete installation.
3.  These models CANNOT be installed in a 
bedroom unless the maximum BTU rating 
of  the  installed  vent-free  log  set  is  less 
than 10,000 Btu/Hr.
4.  Proper air for combustion and ventilation 
(page 7).