Hampton Direct H15-LP1 Manual Do Utilizador

Página de 48
22
Hampton
®
 H15-1 Direct Vent Freestanding Gas Stove
Dura-Vent Basic 
Horizontal Kit # 970
1 90
o
 Elbow
1 Wall 
Thimble 
Cover
1 Horiz. 
Sq. 
Term. 
Cap
DURA-VENT TERMINATION KIT
Planning Your Dura-Vent 
Installation
There are two basic types of Dura-Vent Direct 
Vent System installations: horizontal termination 
and vertical termination. Confi rm the maximum 
horizontal run and maximum vertical rise from 
the diagrams in the "Rigid Pipe Venting Sys-
tems" section. 
When planning your installation, it will be nec-
essary to select the proper length of vent pipe 
for your particular requirements. For horizontal 
installations, determine the minimum clearance 
from the rear of the unit to the wall. It is also 
important to note the wall thickness.  (The 
wall thimble is suitable for 2 x 4 or 2 x 6 wall 
construction.) Select the amount of vertical 
rise desired for "vertical-to-horizontal" type 
installations.  
Warning:  Always maintain required 
clearances (air spaces) to nearby 
combustibles to prevent a fire 
hazard. Do not fi ll air spaces with 
insulation. 
The minimum clearance requirements between 
the outer wall of the vent pipe and nearby com-
bustible surfaces is 1-1/4 inch. Be sure to check 
the vent termination clearance requirements 
from decks, windows, soffi ts, gas regulators, air 
supply inlets and public walkways as specifi ed 
in the "Exterior Vent Terminal Locations" section 
and in your local building codes.
To determine the length of vent pipe required 
for vertical installations, measure the distance 
from the unit fl ue outlet to the ceiling, the ceiling 
thickness, the vertical rise in an attic or second 
storey, and allow for suffi cient vertical height 
above the roof line. 
For multi-storey applications, fi re stops are 
required at each fl oor level. If an offset is 
needed, additional pipe, elbows and supports 
will be required.
Do not exceed the maximum number of elbows.  
One 90
o
 for horizontal terminations and two 45
o
 
for vertical termination.
AstroCap
Part# 946-523/P
Alternate Horizontal 
Termination Caps
Alternate 
Horizontal 
Riser Vent 
Terminal 
Part# 640-530/P
The FPI AstroCap
TM 
is certifi ed for installations using FPI venting systems 
as well as Simpson Dura-Vent® and Direct Vent GS.
The FPI AstroCap
TM
 is a proprietary trademark of FPI Fireplace Prod-
ucts International Ltd.
Dura-Vent® and Direct Vent GS are registered and/or proprietary 
trademarks of Simpson Dura-Vent Co. Inc.
INSTALLATION