Hampton Direct H15-NG1 Manual Do Utilizador

Página de 48
Hampton
®
 H15-1 Direct Vent Freestanding Gas Stove
17
Offset to Vertical Terminations
Venting Arrangements - Horizontal Terminations 
VENTING ARRANGEMENTS
Vertical Terminations Systems for 
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight 
vertical and offset to vertical runs with vertical terminations.
  Maximum two 45
o
 
elbows.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to 
combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Horizontal Terminations for 
All Venting Systems
The shaded areas in the diagram below show all 
allowable combinations of vertical runs with hori-
zontal terminations.  Maximum one 90
O
 elbow (two  
45
elbows equal one 90
o
 elbow).
Propane and Natural Gas: 
Residential, Manufactured and Mobile 
Homes Installations
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
The two diagrams show all allowable com-
binations of straight horizontal  termination 
with one 45
o
 elbow off the unit. Restrictor 
position "A".
12" max. w/AstroCap or Simpson Duravent 
Horizontal Square Termination Cap.
24" max. w/FPI Riser or Simpson Duravent 
Snorkel Termination Cap.
INSTALLATION