IMPORTANT MESSAGE  
SAVE THESE 
INSTRUCTIONS
The  Direct Vent Freestanding Gas Stove must 
be installed in accordance with these instruc-
tions. Carefully read all the instructions in this 
manual fi rst. Consult the building authority 
having jurisdiction to determine the need for a 
permit prior to starting the installation.
Note:  Failure to follow the instructions 
could cause a malfunction of the 
heater which could result in death, 
serious bodily injury, and/or prop-
erty damage.  Failure to follow these 
instructions may also void your fi re 
insurance and/or warranty.
Note: These instructions take precedence 
over Simpson Dura-Vent instruc-
tions.
SPECIFICATIONS
Fuels: 
H15-NG1 is approved for use with 
natural gas.
 
H15-LP1 is approved for use with liq-
uefi ed petroleum gases (propane).
Electrical:  120V  A.C. system.
Optional Circulation Fan:  
 Variable 
speed, 
125/75.
Log Sets:  Ceramic fi bre, 4 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner 
liner) rigid fl ue and termination cap.
MOBILE / 
MANUFACTURED 
HOMES AFTER 
FIRST SALE
This Hampton
®
 product has been tested and 
listed by ITS Testing Services as a Direct Vent 
Room Heater to the following standards:  
CGA-2.17-M91, and ANSI Z21.88B-2003/CSA 
2.33B-2003.
This Direct Vent System Appliance must be 
installed in accordance with the manufacturer's 
installation instructions and the Manufactured 
Home Construction and Safety Standard, Title 
24 CFR, Part 3280, or the current Standard of 
Fire Safety Criteria for Manufactured Home In-
stallations, Sites, and Communities ANSI/NFPA 
501A, and with CAN/CSA Z240-MH Mobile 
Home Standard in Canada.
INSTALLATION
This appliance installation must comply with the 
manufacturer's installation instructions and local 
codes, if any. In the absence of local codes fol-
low the current National Fuel Gas Code, ANSI 
Z223.1 and the current National Electrical Code 
ANSI/NFPA 70 in the U.S.A., and the current 
CAN/CGA B149 Gas Installation Code and the 
current Canadian Electrical Code CSA C22.1 
in Canada.
This Hampton
®
 Mobile/Manufactured Home 
Listed appliance comes factory equipped 
with a means to secure the unit.
This Hampton
®
 Mobile/Manufactured 
Home listed appliance comes equipped 
with a dedicated #8 ground lug to which 
an 18 gauge copper wire from the steel 
chassis ground must be attached.
This appliance may only be installed in 
an aftermarket permanently located, 
manufactured (USA only) or mobile 
home, where not prohibited by local 
codes.
This appliance is only for use with 
the type of gas indicated on the rating 
plate. This appliance is not convert-
ible for use with other gases, unless 
a certifi ed kit is used.
INSTALLATION AND REPAIRS 
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED, 
REPAIRED, INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY 
BY A QUALIFIED SERVICE PER-
SON.  MORE FREQUENT CLEAN-
ING MAY BE REQUIRED DUE TO 
EXCESSIVE LINT FROM CARPET-
ING, ETC.  IT IS IMPERATIVE THAT 
THE CONTROL COMPARTMENT, 
BURNERS AND CIRCULATING 
AIR PASSAGEWAYS OF THE AP-
PLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, 
THE APPLIANCE SHOULD BE 
LOCATED OUT OF TRAFFIC AND 
AWAY FROM FURNITURE AND 
DRAPERIES.
BEFORE YOU START
Safe installation and operation of this appli-
ance requires common sense, however, we 
are required by the Canadian Safety Standards 
and ANSI Standards to make you aware of the 
following:
1)  Provide adequate clearances for servicing, 
proper operation and around the air openings 
into the combustion chamber. 
2)  The appliance must be installed on a fl at, 
solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or it can be 
raised up on a platform to enhance its visual 
impact. The appliance may be installed on 
carpeting, tile, wood fl ooring or other com-
bustible material, because the appliance's 
base extends the full width and depth of the 
appliance. The  Direct Vent Freestanding 
Gas Stove can be installed in a wide variety 
of ways and will fi t nearly any room layout. 
It may be installed in a recessed position, 
framed out into the room, or across a cor-
ner.
3)  The  Direct Vent Freestanding Gas Stove  is 
approved for alcove installations, which meet 
the clearances listed in the "Clearance to 
Combustibles" section.  This unit is approved 
for manufactured home installations, see 
the "Manufactured Mobile Home Additional 
Requirements" and "Rigid Pipe Venting 
Systems" sections for the required vent ar-
rangements. If installed into a manufactured 
home the unit must be bolted down to the 
fl oor. 
4)  This appliance is Listed for bedroom  instal-
lations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
5)  This appliance is Listed for Alcove installa-
tions, maintain minimum Alcove clearances 
as follows,  minimum width of  32-1/2" 
WARNING: FAILURE TO INSTALL 
THIS APPLIANCE CORRECTLY 
WILL VOID YOUR WARRANTY 
AND MAY CAUSE A SERIOUS 
HOUSE FIRE.
CHILDREN AND ADULTS SHOULD 
BE ALERTED TO THE HAZARDS 
OF HIGH SURFACE TEMPERA-
TURES, ESPECIALLY THE FIRE-
PLACE GLASS, AND SHOULD 
STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION.  
YOUNG CHILDREN SHOULD 
BE CAREFULLY  SUPERVISED 
WHEN THEY ARE IN THE SAME 
ROOM AS THE APPLIANCE.  
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE.