Hampton Direct H25-LP1 Propane Manual Do Utilizador

Página de 48
Hampton
®
 H25-1 Direct Vent Freestanding Gas Stove
11
EXTERIOR VENT TERMINAL LOCATIONS
A=  Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) 
B=  Clearance to window or door that may be opened *(12"/30cm)
C= Clearance to permanently closed window *(min. 12"/30cm) 
D= Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal 
(min. 22"/55cm) check with local code.
E=  Clearance to unventilated soffi t (min. 12"/30cm)
F= Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura-Vent Termination Cap (min.12"/30cm), with Riser Vent 
(min. 6"/15cm)
G= Clearance to inside corner: with AstroCap Termination Cap (min.  6"/15cm), with Dura-Vent Termination Cap (min.12"/30cm), with Riser Vent 
(min. 6"/15cm)
H=  Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from the centerline of the regulator.
J=  Clearance to service regulator vent outlet *(min. 36"/90cm)
K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance *(12"/30cm)
L= Clearance to a mechanical air supply inlet *(min. 72"/1.8m)
M= **Clearance above paved sidewalk or a paved driveway located on public property *(min. 84"/2.1m)
N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)***
    
Note: * As specifi ed in CGA B149 Installation Code.  Note: Local codes or  regulations may require different clearances.
**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both 
dwellings.
***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.