DURA-VENT TERMINATION KIT
Planning Your Dura-Vent 
Installation
There are two basic types of Dura-Vent Direct 
Vent System installations: horizontal termination 
and vertical termination. Confi rm the maximum 
horizontal run and maximum vertical rise from the 
diagrams in the "Venting Arrangment" section. 
When planning your installation, it will be nec-
essary to select the proper length of vent pipe 
for your particular requirements. For horizontal 
installations, determine the minimum clearance 
from the rear of the unit to the wall. It is also 
important to note the wall thickness.  (The wall 
thimble is suitable for 2 x 4 or 2 x 6 wall construc-
tion.) Select the amount of vertical rise desired 
for "vertical-to-horizontal" type installations.  
Warning:  Always maintain required 
clearances (air spaces) to nearby 
combustibles to prevent a fire 
hazard. Do not fi ll air spaces with 
insulation. 
The minimum clearance requirements between 
the outer wall of the vent pipe and nearby 
combustible surfaces is 1-1/2", except when 
passing through a wall, ceiling, or at the ter-
mination where the use of a fi restop or wall 
thimble reduces the required clearance to 1". 
Be sure to check the vent termination clearance 
requirements from decks, windows, soffi ts, 
gas regulators, air supply inlets and public 
walkways as specifi ed in the "Exterior Vent 
Terminal Locations" section and in your local 
building codes.
To determine the length of vent pipe required 
for vertical installations, measure the distance 
from the unit fl ue outlet to the ceiling, the ceiling 
thickness, the vertical rise in an attic or second 
storey, and allow for suffi cient vertical height 
above the roof line. 
For multi-storey applications, fi re stops are 
required at each fl oor level. If an offset is 
needed, additional pipe, elbows and supports 
will be required.
Do not exceed the maximum number of elbows.  
One 90
o
 for horizontal terminations and two 45
o
 
for vertical termination.
AstroCap
Part# 946-523/P
Alternate Horizontal 
Termination Caps
Alternate 
Horizontal 
Riser Vent 
Terminal 
Part# 640-530/P
INSTALLATION
The FPI AstroCap
TM 
is certifi ed for installations using FPI venting systems 
as well as Simpson Dura-Vent® and Direct Vent GS.
The FPI AstroCap
TM
 is the proprietary trademark of FPI Fireplace 
Products International Ltd.
Dura-Vent® and Direct Vent GS are registered and/or proprietary 
trademarks of Simpson Dura-Vent Co. Inc.