Desa (V)T32P Manual Do Utilizador

Página de 36
www.desatech.com
108661-01F
3
OPERATING FIREPLACE
FOR YOUR SAFETY READ 
bEFORE LIGHTING
TO TURN OFF GAS 
tO APPLIANCE
1.  Open lower louver panel.
2.  Set selector switch in the OFF position to prevent draining 
battery.
3.  Turn off all electrical power to the appliance if service is to 
be performed.
4.  Push in gas control knob slightly and turn clockwise 
 
to OFF.
5.  Close lower louver panel.
Shutting Off burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing 
one of the following:
1.  Turn gas control knob clockwise 
 to the PILOT 
position.
2.  Set selector switch in the OFF position.
MANUAL LIGHTING 
PROCEDURE
1.  Remove glass door (see Removing/Replacing Glass Door
page 20.)
2.  Follow steps 1 through 8 under Lighting Instructions.
3.  Depress gas control knob and light pilot with match.
4.  Keep gas control knob pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release gas control knob. Follow 
steps 10 through 14 under Lighting Instructions.
5.  Replace glass door (see Removing/Replacing Glass Door, 
page 20).
O
F
  PILOT   
LO 
IH 
O
N
     
    
    
   
Figure 50 - Control Valve
Piezo 
Ignitor
Gas Control 
Knob
Variable Control Knob
 WARNING: If you do not follow these instructions 
exactly, a fire or explosion may result causing property 
damage, personal injury or loss of life.
A.  This appliance has a pilot which must be lighted by hand. 
When lighting the pilot, follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the appliance area 
for gas. Be sure to smell next to the floor because some gas 
is heavier than air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not use any phone 
in your building.
•  Immediately call your gas supplier from a neighbor's 
phone. Follow the gas supplier's instructions.
C.  Use only your hand to push in or turn the gas control knob. 
Never use tools. If the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force 
or attempted repair may result in a fire or explosion.
D.  Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect 
the appliance and to replace any part of the control system 
and any gas control which has been under water.
LIGHTING 
INStRUCtIONS
1.  STOP! Read the safety information above.
2.  Open lower louver panel.
3.  Disconnect the wire that runs from TH to TPTH from the 
control valve.
4.  Turn off all electric power to the fireplace.
5.  Push in gas control knob slightly and turn clockwise 
 
to OFF.
6.  Wait five (5) minutes to clear out any gas. Then smell for 
gas, including near the floor. If you smell gas, STOP! Follow 
“B” in the safety information above. If you don't smell gas, 
go to the next step.
7.  The pilot is located by the main burner and should not 
require accessing for lighting.
8.  Turn gas control knob counterclockwise 
 to PILOT.
9.  Push in gas control knob all the way and hold. Immediately 
light the pilot by repeatedly depressing the piezo spark 
ignitor until a flame appears. Continue to hold for about 
one (1) minute after the pilot is lit. Release gas control knob 
and it will pop back. Pilot should remain lit. If it goes out, 
repeat steps 5 through 8.
•  If gas control knob does not pop up when released, stop 
and immediately call your service technician or gas 
supplier.
•  If the pilot will not stay lit after several tries, turn the gas 
control knob to OFF and call your service technician or 
gas supplier.
10.  Reconnect the wire that runs from TH to TPTH to the 
control valve.
11.  Turn on all electric power to the fireplace.
12.  Turn gas control knob counterclockwise 
 to ON.
13.  This valve is equipped with a HI/LO feature. Set fireplace 
input as desired.
14.  Close lower louver panel.