Desa C36EMW Manual Do Utilizador

Página de 15
                                                                                                        -2 -                                           
For more information, visit www.desatech.com
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INTRODUCTION 
BEFORE BEGINNING THE INSTALLATION OF THE 
FIREPLACE, READ THESE INSTRUCTIONS THROUGH, 
COMPLETELY. 
♦  This DESA fireplace and its components are safe 
when installed according to this installation manual. 
Unless you use DESA components, which has been 
designed and tested for the fireplace system, you may 
cause a fire hazard. 
♦  The DESA warranty will be voided by and DESA 
disclaims any responsibility for the following actions: 
a) Modification of the fireplace, components, doors, 
blower, fans, air inlet system and damper control.  
b) Use of any component part not manufactured or 
approved by DESA in combination with a DESA 
fireplace system. 
PROPER INSTALLATION is the most important step in 
ensuring safe and continuous operation of the fireplace.  
Consult the local building codes as to the particular 
requirements concerned with the installation of all factory 
built fireplaces.  Although grounding may not be required by 
code the manufacturer recommends it. 
 
 
 
 
 
 
 
 
 
 
 
This fireplace is not intended to be used as a substitute for 
a furnace to heat an entire home.  Use for supplemental 
heat only. 
 
USE SOLID WOOD OR PROCESSED SOLID FUEL 
FIRELOGS ONLY. 
 
 
 
 
 
 
 
 
 
 
 
 
SELECTING LOCATION 
To determine the safest and most efficient location for the 
fireplace, you must take into consideration the following 
guidelines: 
1.)  The location must allow for proper clearances (see 
figures 1 & 2). 
2.)  Consider a location were the fireplace would not be 
affected by drafts, air conditioning ducts, windows or 
doors. 
3.)  A location that avoids the cutting of joists or roof 
rafters will make installation easier. 
4.)  An outside air kit is included with this fireplace.  For 
more details refer to section on outside air kit 
installation on page 4. 
 
 
 
 
MINIMUM CLEARANCES TO COMBUSTIBLES 
•  Back and side of fireplace --------------     ¾”   minimum 
Note: The ¾” clearance is not required at the nailing flanges 
•  Floor* -------------------------------------    0”    minimum 
*See step 2 of  “Installing the Fireplace” on page 3 
•  Perpendicular Wall to Opening of unit -   12” minimum 
•  Top Spacers ------------------------------   0”    minimum 
•  Mantel Clearances --------------    see page 8    “Mantels” 
•  Chimney Outer Pipe Surfaces ---------   1”     minimum 
 
 
 
 
MINIMUM / MAXIMUM CHIMNEY HEIGHT 
The minimum height of the chimney, measured from the base 
of the fireplace to the flue gas outlet of the termination, is 11.5 
feet for straight flue or a flue with one elbow set.  The 
maximum distance between elbows is 2 feet.  For systems 
with 2 elbow sets, minimum height is 22 feet.  The maximum 
height of any system is 28 feet.  This measurement includes 
the fireplace, chimney sections and the height of the 
termination assembly at the level of the flue gas outlet (see 
page 6, figure 15). 
FRAMING AND INSTALLING THE FIREPLACE 
STEP 1: Frame the opening for the fireplace using the 
dimensions shown in figures 1 & 2. 
STEP 2: If the fireplace is to be installed directly on carpeting, 
tile (other than ceramic), or any combustible material other 
than wood flooring, the fireplace must be installed upon a 
metal or wood panel extending the full width and depth of the 
fireplace. 
FOR YOUR SAFETY 
•  Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other
appliance. 
•  Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies. 
•  Do not place clothing or other flammable materials on
or near the appliance. 
•  NEVER leave children unattended when a fire is
burning in the fireplace. 
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury,
property damage, or loss of life.  Refer to this manual
for assistance or additional information.  Consult a
qualified installer or local distributor. 
CHECK HUD REQUIREMENTS BEFORE
INSTALLING THIS FIREPLACE. 
WARNING:  Do not install a fireplace insert in
this box unless the manufacturers instructions with
the insert specifically state this fireplace has been
tested for use with the insert. 
This wood burning fireplace complies with UL 127
standard as a FACTORY BUILT FIREPLACE. 
WARNING: Do not pack required air spaces with
insulation or other materials. 
This Model fireplace C36EMW meets the construction
and safety standards of HUD for application in mobile
homes when installed according to these instructions. 
CAUTION: The structural integrity of the mobile home
floor, and ceiling/roof must be maintained. 
WARNING: Do not install in a bedroom.
WARNING:  When processed wood fuel fire logs
are used, do not poke or stir the logs while they are
burning.  Use only fire logs that have been evaluated for
the application in fireplace and refer to fire log warnings