grease  is  recommended  as  lubricants  for  pumps  operating  in
both wet and dry locations. Mixing of different brands of grease
should  be  avoided  due  to  possible  chemical  reactions  between
the  brands  which  could  damage  the  bearings.  Accordingly,
avoid  grease  of  vegetable  or  animal  base  which  can  develop
acids,  as  well  as  grease  containing  rosin,  graphite,  talc  and 
other  impurities.  Under  no  circumstances  should  used  grease 
be reused.
Over lubrication should be avoided as it may result in overheat-
ing and possible bearing failure. Under normal application, ade-
quate  lubrication  is  assured  if  the  amount  of  grease  is  main-
tained  at  1/3  to  1/2  the  capacity  of  the  bearing  and  adjacent
space surrounding it.
In  dry  locations,  each  bearing  will  need  lubrication  at  least
every  600  hours  of  running  time  or  every  6  to  12  months,
whichever  is  more  frequent.  In  wet  locations  the  bearings
should  be  lubricated  at  least  after  every  300  hours  of  running
time or every 4 to 6 months, whichever is more frequent. A unit
is  considered  to  be  installed  in  a  wet  location  if  the  pump  and
motor are exposed to dripping water, to the weather, or to heavy
condensation such as is found in unheated and poorly ventilated
underground locations.
Oil lubricated bearings are optional on MODEL 344 pumps. A
fixed  oil  level  is  maintained  with  the  power  frame  by  an  oiler
which allows visual indications of reserve oil.
At  initial  installation  and  before  starting  a  unit  that  has  been
shut  down  for  repairs  or  for  any  extended  length  of  time,  run
enough 10W-30 weight motor oil through the oiler to maintain a
constant oil level to insure that the bearing will never be with-
out an oil supply. Oil will have to be added at intervals to main-
tain a constant level in the oiler. This interval can only be deter-
mined by experience.
Under  working  conditions,  oil  will  breakdown  and  need  to  be
replaced  at  regular  intervals.  The  length  of  these  intervals  will
depend on many factors. Under normal operation, in clean and
dry  locations,  the  oil  should  be  changed  about  once  a  year.
However, when the pump is exposed to dirt contamination, high
temperatures  (200°F.  or  above)  or  a  wet  location,  the  oil  may
have to be changed every 2 to 3 months.
Use  normal  fire  caution  procedures  when  using  any
petroleum cleaner.
REPAIRS
Before  starting  any  work,  insure  the  electrical  power  is  locked
out, the system pressure has been lowered to 0 psi and tempera-
ture of the unit is at a safe level.
The pump may be disassembled using the illustrations and text
provided. Although complete disassembly is covered, it will sel-
dom  be  necessary  to  completely  disassemble  your  Aurora
pump.
The  illustrations  accompanying  the  disassembly  instructions
show  the  pump  at  various  stages  of  disassembly.  The  illustra-
tions are intended to aid in the correct identification of the parts
mentioned in the text.
Inspect  removed  parts  at  disassembly  to  determine  if  they  can
be reused. Ball bearings that turn roughly or show wear should
be replaced. Cracked castings should never be reused. Scored or
worn  pump  shafts  should  be  replaced.  Gaskets  should  be
replaced at reassembly simply as a matter of economy. They are
much less expensive to replace routinely than to replace singly
as the need arises. 
CAUTION
A. Assembled Units.
Model 342A
Model 341A
Model 344A
Warning:
Sudden Start-Up Hazard
Disconnect  and  lockout  power  source  before  servicing.
Failure  to  follow  these  instructions  could  result  in  serious
personal injury, death or property damage.
Warning:
Hot Surface Hazard
If  pumping  hot  water,  insure  guards  or  proper  insulation  is
installed  to  protect  against  skin  contact  to  hot  piping  or
pump components. Failure to follow these instructions could
result in serious personal injury, death or property damage.
Warning:
High Pressure Hazard
The  pump  is  rated  at  a  maximum  of  175  psi  at  150°F.  Do
not  exceed  this  pressure.  Install  properly  sized  pressure
relief valves in system.  Failure to follow these instructions
could  result  in  serious  personal  injury,  death  or  property
damage.
Warning:
Spraying Water Hazard
When servicing pump replace all gaskets and seals. Do not
re-use  old  gaskets  or  seals.  Failure  to  follow  these  instruc-
tions could result in serious personal injury, death or proper-
ty damage.