Aquacal AT120 Manual Do Utilizador

Página de 36
 
19
TROUBLESHOOTING 
 
HEAT PUMP NOT RUNNING 
Is the display lit?  If not, ensure the main breaker (located at the power supply 
panel) and the disconnect switch (located near the heat pump) are both turned ON. 
Does the display read “Flo”?  If so , check to be sure that the circulating pump is 
operating and the filter is clean.  There may also be a valve positioned incorrectly 
allowing water to by-pass the heat pump; be sure water is flowing through the 
heater. 
Does the display read “OFF”?  If so the desired water temperature is set below 
60°F.  Raise the desired water temperature above the actual water temperature and 
the unit should start after a 3-to-4 minute delay. 
  If the display is showing any other fault codes, or is blank, contact AquaCal at        
  800-786-7751.  Service may be required.
 
HEAT PUMP RUNNING BUT NOT HEATING 
Is the air blowing out of the top of the unit noticeably cooler than the surrounding 
air?  (A 9°F to 12°F difference is typical.) If not, call AquaCal for service at      
800-786-7751. 
Be sure all air coil surfaces are free from obstructions; low roof overhangs, 
landscaping, walls, fences, etc.  The heat pump needs good airflow to operate at 
peak efficiency. 
How long are you running your circulating pump each day?  Cooler weather 
conditions, or heating to a higher temperature, may necessitate running the heat 
pump for a longer period of time.  A pool blanket can be useful in permitting 
shorter run times, in turn leading to substantial energy cost savings.  
What is the air temperature?  Your heat pump may be in the defrost mode if air 
temperatures are below 50°F.  The digital display will read “FS” if the unit is 
defrosting or air temperatures are too cold.