Aquacal 75 Manual Do Utilizador

Página de 6
 
 
Page 5 
SECTION 5 -  TROUBLESHOOTING 
ERROR CODES 
SYMPTOM RULE 
OUT 
RESOLUTION 
"FLO" 
 
 
Insufficient Water Flow 
Step 1: 
Confirm water pump is on and water valves are in the correct position to allow 
water to flow through Heat Pump. If error persists, proceed to next step. 
Filtration Dirty 
Step 2: 
Confirm filtration system is clean. Backwash if needed. If error persists, 
proceed to next step. 
Insufficient water flow 
through heater or 
circulation pump is off 
Possible Water 
Pressure Switch 
Step 3: 
Request Service 
“CEr” Error 
 
 
Communication Fault 
N/A 
Request Service 
“CSE” Error 
 
 
Control System Error 
N/A 
Request Service 
“dPC” Error 
 
 
Defrost Sensor Shorted 
N/A 
Request Service 
“dPO” Error 
 
 
Defrost Sensor Open 
N/A 
Request Service 
“FS” Error 
 
 
Unit in defrost mode. 
Normal defrost mode 
Step 1: 
If error persists after air temperature is over 50° F, request service. 
“HP” Error 
 
 
Insufficient Water Flow 
Step 1: 
Confirm water pump is on and water valves are in the correct position to allow 
water to flow through Heat Pump. If error persists, proceed to next step. 
Filtration Dirty 
Step 2: 
Confirm filtration system is clean. Backwash if needed. If error persists, 
proceed to next step. 
High Pressure. 
Possible Refrigerant 
Issue 
Step 3: 
Request Service 
“HP5” Error 
 
 
Equipment has 
registered high pressure 
five times and locked. 
Insufficient Water Flow 
and/or Filtration Dirty 
Step 1: 
Follow steps outlined in “HP” error, then reset circuit breaker to clear error. If 
error persists, request service. 
“LP” Error 
 
 
Refrigerant Issue 
N/A 
Request Service 
“LP5” Error 
 
 
Refrigerant Issue 
N/A 
Request Service 
“OTA” 
 
 
Over Temperature 
Alarm 
 
Temperature over  
110° F (Unit Locked) 
Other heating 
equipment 
Check if alternate heater (such as a solar heater) is heating water leading to 
heat pump. If “yes”, turn off alternate heater and check if error clears. If error 
persists, request service. 
“PC” Error 
 
 
Water Temperature 
Sensor Shorted 
N/A Request 
Service 
“PO” Error 
 
 
Water Temperature 
Sensor Open 
N/A Request 
Service