Sanyo CL4232 Manual Do Utilizador

Página de 66
– 10 –
SM830078
(2)
Major Component Specifications
(A)
Indoor Unit
2. SPECIFICATIONS
DATA SUBJECT TO CHANGE WITHOUT NOTICE
MODEL No.
XS4232
Source
230 - 208 V / 1 phase / 60 Hz
Remote  controller (Accessory)
RCS - 5PS4U
Controller P. C. B Ass'y
CR - TS2432
Control circuit fuse
250 V, 3 A
Switch Ass'y
SW - X363GS
Fan (Number … diameter)
in.
(mm)
Turbo (1…19-9/32 (490))
Fan motor
Model
SFG6X - 61A3P
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High)
rpm
6 … 560
Nominal output
W
60
Coil resistance
Ω
BRW - WHT
:
71.1
,
ORG - YEL
:
22.7
(Ambient temperature 68 
°
F)
WHT - VLT
:
8.7
,
VLT
- PNK
:
43.2
VLT
- ORG
:
13.3
,
YEL
- BLK
:
54.32
Safety device
Operating temperature
Open
°
F
266
±
14.4
Close
°
F
174.2
±
27
Run capacitor
VAC,
µ
F
440 V , 6 
µ
F
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows … Fins per inch
2 … 14.9
Face area
ft.
2
(m
2
)
5.17 (0.48)
Panel
Model No.
PNR - XS3632
Indicator Lamp Ass'y
IND - XS3632
Auto louver motor
MT8 - 3C
Auto louver motor … Rated
V, W,
rpm
240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 
°
F)
Ω
16,430 
Ω
 
±
 8 %