Sanyo KGS1411 Manual Do Utilizador

Página de 100
4
2-2.  Major Component Specifications
2-2-1.  Indoor Unit
Indoor unit   KGS1411
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Control PCB
Part No.
POW-KGS14A, B
Controls
Microprocessor
Control circuit fuse
115V
Flap Motor
Type
Stepping motor
Model
MP24GA1
Rating
DC12V
Coil resistance (ambient temp. 77°F (25°C))
Ω
WHT – BLU (respectively 4 wires): 380 ± 7%
Heat Exchanger Coil
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
inch (mm)
1/16 (1.4)
Face area
ft
2
(m
2
)
1.40 (0.130)
Fan & Fan Motor
Type
Cross-flow
Q’ty … Dia. and length
inch (mm)
1 … ø 95 / L617 (ø 3-3/4 / L24-9/32)
Fan motor model … Q’ty
KFV4-21HIP … 1P
Nominal output
W
15
Coil resistance (ambient temp. 68°F (20°C))
Ω
BLU – BRN: 104.9
BLU – PNK: 128.0
Safety devices
Type
X23
Operating temp.
Open °F (°C)
259 (126) ±4 (±2)
Close
Run capacitor
µF
3.5
VAC
180
Remote Control Unit
RCS-IRS2U