Sanyo SPW-T253G56 Manual Do Utilizador

Página de 71
– 17 –
SM830043
1
1. Specifications
1-2 Major Component Specifications
(A)
Indoor Unit
MODEL No.
SPW-T483G56
SPW-T483GS56
Source
220 - 230 - 240 V  / 1 phase / 50 Hz
Remote Controller (Accessory)
RCS - T251G
RCS - 5PS3E
Controller P.C.B. Ass’y
CR - X363GS
Switch Ass’y
SW - X363GS
Fan (Number…diameter)
mm
Centrifugal (4...ø150)
Fan Motor
Model…Nominal output
W
KFG4Q - 101D5P...100 W
Source
220 - 230 - 240 V / 1 phase / 50 Hz
No. of pole…r.p.m. (230 V, High)
               rpm.
4...1,212
Coil resistance
Ω
BRN – WHT
:
43.3
,
ORG – YEL
: 349.3
(Ambient temperature 20 
°
C)
WHT – VLT
:
16.6
,
VLT – PNK
:
40.8
VLT – ORG
:
24.5
Safety device
Operating temperature
Open  
°
C
130 
±
 5 
°
C
Close  
°
C
    Differential 15 deg. (min.)
Run capacitor
VAC, 
µ
F
440 V, 4.5 
µ
F
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows…fin pitch
mm
3…1.7
Face area
 m
2
0.34
Auto louver motor
MC8 D
Auto louver motor...Raterd
V, Hz, W, rpm.
220 - 240 VAC, 50 Hz, 3 W, 3.3 rpm. 8P
Coil resistance (at 25 ˚C)
Ω
14,900 
Ω
 
±
 8 %
Dew proof heater
V, W
240 V, 17 W