Your portable air conditioner is designed to exhaust condensate 
water that is collected from the air. This water, in either gaseous or 
droplet form, will be expelled out the exhaust port of the unit. 
Please take this into account when deciding how to vent it. 
 
1. The exhaust hose supplied with the portable air conditioner can 
be extended up to 48 inches; however for maximum efficiency, use 
the shortest length possible. 
 
2. Try to prevent any kinks or bends in the exhaust hose. Kinks or 
bends may trap exhaust air which can radiate heat into the room or 
potentially cause the portable air conditioner to overheat and shut 
itself off.
 
 
3. The exhaust hose supplied with the portable air conditioner has 
been specifically designed for this air conditioner. Do not lengthen 
the hose by adding additional hoses or attachments or replace it 
with any other hose. 
Do not lengthen the
exhaust hose by adding
additional hoses or
attachments.
 
Warning: Longer hoses are not recommended.
 
 
Draining the Unit 
 
When the portable air conditioner is in cooling mode, or dehumidify 
mode, it will remove moisture from the air. The condensed water 
from the air will be collected in an internal reservoir and will be 
evaporated and exhausted out of the exhaust hose. However, in 
very humid conditions, the internal reservoir may fill completely. 
This causes the air conditioner to turn off to avoid overflowing the 
internal reservoir. The WATER indicator will light up on the Control 
Panel. 
Direct drainage 
1. Remove the rubber drain plug from the drain port. 
2. Connect a drain hose to the drain port. 
The portable air conditioner will now drain through the drain hose. 
Please note that this unit has no drain pump; all water will drain 
with gravity only, i.e., only “downhill.”
 
Notes about the Exhaust 
hose