Fan
Hub
Setscrew
Motor
Figure 10 - Fan Cross Section
SERVICE PROCEDURES
Continued
14. Dry fan thoroughly.
15. Replace  fan  on  motor  shaft.  Place  set-
screw on flat of shaft. See chart in Figure 
10  for  distance  of  fan  hub  from  end  of 
motor shaft. Tighten setscrew firmly (40-
50 inch-pounds).
16. Remove screws securing motor mount to 
shell.
17. Pull motor and fan from shell. Turn motor 
and fan around. Carefully place back in 
shell. Note: Fan will go into shell first.
18. Line  up  mounting  holes  in  shell  with 
holes on motor mount. Replace 4 screws 
through shell and motor mount.
19. Route motor wires through hole in top of 
shell (see Figure 7, page 8).
0. Reconnect motor wires to the same posts 
on terminal block as removed in step 3, 
page 8 (see Figure 7, page 8).
1. Replace top cover.
. Replace fan guard.
SPECIFICATIONS
all Models
•  Propane/LP Gas
•  Gas Supply Pressure to Regulator:
  Max - Bottle Pressure, Min - 5 psig
  (17.4 kPa)
•  Gas Supply Pressure Regulator Out:
  0 psig (137.9 kPa)
•  Electrical Input: 120V, 60 Hz, 1Ø, 3a
•  Direct Spark Ignition
•  Minimum Ambient Temp. Rating:
  0° F (-17.8° C)
55,000 Btu/Hr Models
•  30 - 55,000 Btu/Hr (8.8 - 16.1 kW)
•  Fuel Consumption:
  1.4 - .6 pounds/hr (0.70 - 1.8 kg/hr)
•  Primary Flame Control:
  Thermocouple operated gas valve
•  Heated Air Output: 300 CFM (8.49 m
3
/min)
85,000 Btu/Hr Models
•  50 - 85,000 Btu/Hr (14.6 - 5.0 kW)
•  Fuel Consumption:
  .3 - 3.9 pounds/hr (1.04 - 1.77 kg/hr)
•  Primary Flame Control:
  Thermocouple operated gas valve
•  Heated Air Output: 350 CFM (9.91 m
3
/min)
125,000 Btu/Hr Models
•  75 - 15,000 Btu/Hr (1.9 - 36.6 kW)
•  Fuel Consumption:
  3.5 - 5.8 pounds/hr (1.59 - .63 kg/hr)
•  Primary Flame Control:
  Thermocouple operated gas valve
•  Heated Air Output: 350 CFM (9.91 m
3
/min)
170,000 Btu/Hr Models
•  15 - 170,000 Btu/Hr (36.6 - 49.8 kW)
•  Fuel Consumption:
  5.8 - 7.9 pounds/hr (.63 - 3.6 kg/hr)
•  Primary Flame Control:
  DSI Flame Rectification
•  Heated Air Output: 450 CFM (1.74 m
3
/min)
Figure 9 - Fan, Motor Shaft and Setscrew 
Identification
Motor 
Shaft
Fan
Setscrew
Model
Distance A
55
0.19" (4.8 mm)
85
0.5" (1.7 mm)* or 
0.9" (.9 mm)*
15 0.5" (1.7 mm)* or 
0.9" (.9 mm)*
170
0.5" (6.4 mm)
Motor 
Shaft
* Depending 
on Motor Shaft