Maintenance 
Drainage: 
When unit running in cooling mode, mostly the water can be drained out through the 
exhausted hose, however, if the environment is too humid, condensed water can not 
completely  be  drained  out  by  this  way.  In  this  case,  we  need  to  drain  the  water. 
While water tray is full, error code “E4” will appear in display, meanwhile, the cooling 
mode will stop running automatically, and fan will stop in 3 minutes accordingly as 
well. If want to start cooling mode, please use the following way to empty the water 
 
Drainage  Hole
Rubber Plug
Drainage K nob
Water Plate
 
A. water plate drainage 
1. turn off the unit 
2. horizontally place water plate underneath drainage hole; 
3. disconnect drainpipe through drainage knob and rubber plug, water will 
    Automatically flow out; 
4. when the water is empty, push rubber plug back to the drainage hole; 
5. connect drainage pipe by spinning the knob; 
6. restart the unit 
 
 
Normally  it  is  no need  to  drain  the  water because  the unit  has  the  water  pump  to 
pump the condensed water from the water tray onto the condenser to evaporate the 
water unless the air is too humid. 
 
 
 
 
-16-