Working Principle 
 
Refrigerant  with  low  temperature  and  low  pressure  is  compressed  by  the 
compressor  to  high  temperature  and  high  pressure  vapour,  then  cools  in  the 
condenser (This is a forced air cooling process: room air passes condenser surface, 
absorbs the refrigerant's heat in the condenser by heat exchange, then the room air 
warms up and the warm air is exhausted through the air exhaust duct,) to become 
high pressure liquid. The liquid flows through capillary tube to lower its pressure to 
become low temperature low pressure liquid. After absorbing the heat of air in the 
surface of evaporator (A forced air cooling process too: room air passes evaporator 
surface, its heat is absorbed by refrigerant in tube, it cools down and flows into room 
to  lower  the  room  temperature).  The  low  temperature  low  pressure  liquid  is 
evaporated  in  the  evaporator.  The  refrigerant  becomes  vapour  and  flows  back  to 
compressor. Then the refrigerant vapour is compressed in compressor again. Thus 
the room temperature is lowered by circulating this operation. 
fan motor
hot air
air flow2(air inflow from back)
condenser
compressor
upper fan 
cool air 
(heating)
lower fan 
motor
lower fan
capillary 
tube
air flow1
evaporator
 
 
 
 
 
 
 
 
 
-3-