AQUATROL ZONE SYNCHRONIZING BOILER RESET CONTROLS
Automation and Control Solutions
Honeywell International Inc.
Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North
35 Dynamic Drive
Golden Valley, MN  55422
Toronto, Ontario  M1V 4Z9
customer.honeywell.com
® U.S. Registered Trademark
© 2009 Honeywell International Inc.
69-1979—04 M.S.  Rev. 09-09 
USER MENU STRUCTURE
Press the Menu button on the keypad to display the User Menu. Fig. 3 illustrates all possible User Menu selections.
Fig. 3. User Menu Structure.
AQUATROL® is a registered trademark of Honeywell International Inc.
M27750
BOILER UNITS:     °F  
ZONE UNITS:       °F
TIME DISP:       12H
D.S.T.:       ENABLE
YEAR:           2008
MONTH:           JAN
DATE:              1
DAY:          MONDAY
TIME:         12:00A
HOMEPAGE:     DETAIL
BACKLIGHT:      AUTO
POWER FAILURE
NOTICE:    BACKLIGHT
PREFERENCES / TIME
SYSTEM STATUS      
PREFERENCES/TIME   
ZONE SETTINGS      
PROGRAM SETTINGS   
STATISTICS         
USER MENU
AUX IN EM.SHUT
BOILER:        IDLE
CALL FOR DHW
CALL FOR HEAT
DHW DISABLE
LOST ZONE A-1
 ...
LOST ZONE D-16
NO DHW PROBE
NO OUTDOOR PROBE
NO RETURN PROBE
NO SUPPLY PROBE
SHORT CYCLE PROT
VALVE INIT
WATER READY
WWSD ACTIVE
SYSTEM STATUS      
1
ZONE             A-1
ROOM TEMP          
FLOOR TEMP
SETPOINT:         70
FLOOR SETPT:      70
HEAT/COOL STATUS
SETBACK:           7
SETPOINT MAX:    100
SETPOINT MIN:     41
FLOOR LIM  HI:   100
FLOOR LIM LO:     41
SETPOINT VACANCY
HEAT:             41   
SETPOINT VACANCY
COOL:            100   
CHANGEOVER:        2
KEYBOARD:     UNLOCK
ZONE SETTINGS (All or Single)
2
ARE YOU SURE?
      NO YES
MON WAKE       6:00A
MON LEAVE      8:00A
MON RETRN      4:30P
MON SLEEP     10:00P
...
SUN WAKE       6:00A
SUN LEAVE     --:-- 
SUN RETRN     --:-- 
SUN SLEEP     10:00P
ALL WAKE       6:00A
ALL LEAVE      8:00A
ALL RETRN      4:30P
ALL SLEEP     10:00P
COPY TO ALL DAYS    
COPY WAKE           
COPY LEAVE          
COPY RETRN          
COPY SLEEP          
MODE:           AUTO
EDIT ALL DAYS       
EDIT DAILY          
PROGRAM SETTINGS
EDIT ALL DAYS
EDIT DAILY
LAST DATA RESET: 2000 JAN 01
BOILER FIRE ACTIV:       0H
BOILER PUMP ACTIV:       0H
DHW PUMP ACTIV:          0H
AUX PUMP ACTIV:          0H
AUX OUT ACTIV:           0H
ZONE                    A-1  
ACTIV:                   0H 
STATISTICS
3
4
5
1
THE  SYMBOLS INDICATE ADDITIONAL SELECTIONS ARE POSSIBLE. 
THE FACTORY DEFAULT VALUES ARE SHOWN.
TEMPERATURE VALUES ARE SHOWN IN DEGREES FAHRENHEIT, 
WHICH IS THE FACTORY DEFAULT TEMPERATURE UNIT.
EITHER HEAT OR COOL DISPLAYS DEPENDING ON THE SYSTEM’S STATUS.
FACTORY DEFAULT TIMES FOR MON THROUGH FRI.
FACTORY DEFAULT TIMES FOR SAT AND SUN.
2
3
4
5
EDIT ALL ZONES      
EDIT SINGLE ZONE    
ARE YOU SURE?
       NO YES