COOK CHILL SYSTEMS
Cook/Chill Systems
SECT.
XIV
PAGE 
53
0907
GAS FIRED STEAM BOILERS
MODELS:
 GFB-6
 GFB-15  GFB-30  GFB-60
 GFB-10  GFB-20  GFB-50
Cleveland Standard Features
I Complete skid-mounted and piped, gas fired Steam Boiler with
Vertical Return System and Blow Down Separator
I Available for Pressure Ratings from 15 to 150 psi (specify
required operating pressure)
I Vertical Tubeless design
I Fully insulated Boiler with top mounted, down-fired burners
I High Temperature Insulation assists thermal efficiency of 80%
I Spinning Cyclonic Flame travels down the entire length of the
Combustion Chamber
I Top Flame Retainer increases occupancy time of flue gases to
complete combustion process
I Operating Pressure Control and High Limit Pressure Control
with Manual Reset
I Water Column with Water Gauge Assembly
I All necessary valves are included
I Automatic Water Feed System with probe type Water Level
Controls and single phase Motor for Pump
I Steam Outlet conveniently located at top of Boiler
I Control Panel factory mounted and wired, ready for power con-
nection
I Built and stamped to A.S.M.E. Code 
I Registered with the National Board of Boiler & Pressure Vessel
Inspectors
I Accepted for use in U.S.D.A. Inspected Facilities
Options & Accessories
Ë Stainless Steel outer Jacket
Ë Automatic Boiler Blow-down Controls
Ë Applicable Controls to meet the various special insurance,
local, state or federal code requirements
Ë Electric heated Steam Boilers
Ë Oil-fired Steam Boilers 
Ë Cooling Kit for boiler drain
Ë Aquastat automatic drain cooling kit
Ë Larger models availabe on request
Shall be CLEVELAND Model GFB -____, gas-fired, vertical, tube-
less LARGE STEAM BOILER System, _____H.P. (horse power);
Complete with Power Burners; Skid mounted and piped with
Vertical Condensate Return System and Blow-Down Separator
Package;  Factory assembled as a self-contained unit, in accor-
dance to U.L. requirements, and A.S.M.E. Section 1 (one) Code;
Guaranteed production of  _______ pounds of Steam per hour at
212˚F.
Short Form Specifications