IDEAL INDUSTRIES HE9 Manual Do Utilizador

Página de 52
4
 classic 
HE 
Installation & Servicing
GENERAL
CAUTION.
  To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance, care should be taken when handling edges of sheet steel components
Boiler Size
HE9
HE12
HE15
HE18
Gas  supply  connection
(in. BSP)
Rc 1/2 (1/2)  1/2" (BSP Female)
Flow connection
22mm
copper
Return connection
22mm
copper
Maximum  static  water  head
   m (ft.)
30.5  (100)
Minimum  static  water  head
    m (ft.)
 0.45 (1.5)
Electrical  supply
230 V   50 Hz  Boiler power consumption; 100W
Fuse  rating
External; 3A          Internal; F1A to BS.4265
Water content
litre (gal.)
3.0 (0.67)
3.95 (0.87)
Packaged Weight
kg (lb)
45 (99)
50 (110)
Maximum installation weight
 kg (lb)
40 (88)
45 (99)
Boiler size
Height   mm (in.)
700 (27.5)
Width   mm (in.)
380 (15.0)
Depth   mm (in.)
280 (11.25)
Flue duct diameter
mm (in.)
100 (4.0)
Flue duct length (max)
m (ft)
3 (9.8)
Note. Gas consumption is calculated using a calorific value of
38.7 MJ/m
3
 (1038 Btu/ft
3
) gross or 34.9 MJ/m
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different calorific value:-
a. FOR L/S - divide the gross heat input (kW) by the gross C.V.
of the gas (MJ/m
3
)
b. FOR FT
3
/H - divide the gross heat input (Btu/h) by the gross
C.V. of the gas (Btu/ft
3
)
Table  1 - General Data
*
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.  The test data from which it has been calculated have been certified by a notified body.
Table  2 - Performance Data
Key to symbols
GB 
= United Kingdom
IE = Ireland   (Countries of destination)
PMS = Maximum operating pressure of water
C
12 
C
32 
= A room sealed appliance designed for connection via
ducts to a horizontal or vertical terminal which admits
fresh air to the burner and discharges the products of
combustion to the outside through orifices which, in
this case, are concentric. The fan is down stream of
the combustion chamber.
I
2H
=
An appliance designed for use on 2nd Family gas,
Group H only.
Boiler Size
HE9
HE12
HE15
HE18
Input 'Q'
Nett CV   kW (Btu/h)
9.4  (32,100)
12.6  (43,000)
15.7  (53,600)
18.9  (64,500)
Gross CV   kW (Btu/h)
10.5  (35,800)
14.0  (47,800)
17.4  (59,400)
20.9  (71,300)
Gas Consumption l/s (cu.ft/h)
0.27 (34.3)
0.36 (45.8)
0.45 (57.2)
0.54 (68.7)
Output 'P
70
o
C Mean Water temp.   kW (Btu/h)
9.0  (30,700)
12.0  (40,900)
15.0  (51,200)
18.0  (61,400)
40
o
C Mean Water temp.   kW (Btu/h)
9.8  (33,400)
13.1  (44,700)
16.2  (55,300)
19.4  (66,200)
Burner Setting Pressure (Hot)
mbar (in w.g.)
12.0 (4.8)
10.4 (4.2)
12.3 (4.9)
12.7 (5.1)
Seasonal efficiency (SEDBUK) *
Band B
[87.2]%
[87.2]%
[86.8]%
[86.8]%
NOx classification
Class 3
Class 2
Class 1
Class 1
201850-6.pmd
21/02/2008, 12:57
4