5.  -Carburetor out of adjustment (decrease high-fire screw). 
 
     -Cold flue. 
 
     -Flame set too high (flame impinging on baffle too much). 
 
     -Faulty gasket (door rope, glass seal, or relief plate seal). 
 
     -Excessive residue in burner bottom. 
 
 
6.  -High wind, or unstable draft condition. 
 
     -Incorrect carburetor setting (increase low-fire screw). 
 
     -Faulty carburetor. (rare condition) 
 
 
7.  -Abnormally high, gusty winds (If you live in a windy area, a draft stabilizer                                 
 
      may need to be installed in the pipe to compensate). 
 
     -A wind-directional cap or vacuum cap may be helpful to prevent wind gusts and 
 
      down drafts from affecting pressure. 
 
 
8.  -No oil in tank. 
 
     -Valve in fuel supply line shut inadvertently. 
 
     -Fuel supply blocked (plugged filter, frozen water). 
 
     -Carburetor on/off lever tripped. 
 
 
9.  -Stove door having been open for a while and then shut (a roaring noise can occur for 
 
      a short period until draft stabilizes). 
 
     -Draft pressure too high - adjust carburetor to decrease high flame size, or add a tee  
 
      in connector pipe with a draft stabilizer 
 
          10.  -Carbon deposits (operate de-coking rod). 
 
     -Draft pressure too high. 
 
          11.  -Carburetor adjusted too high, allowing too much flame impingement on stove top.
 
     -Flue plugged or dirty. 
 
     -Dirty burner or plugged fuel inlet (operate de-coker/clean burner bottom) 
 
     -House pressure problem (inadequate supply of air to stove, or fans operating in the  
 
      house increasing negative house pressure). 
 
     -Faulty or deteriorated catalyst. 
 
     -Blocked or inhibited air supply to stove (check outside air supply to stove or room). 
 
     -Faulty gasket (door rope, glass seal, relief plate seal, or burner gasket).  
 
 
 
12.  -Oil leaking from any connection. 
 
       -Poorly adjusted burner 
 
       -low flue pressure due to chimney size or geographic conditions affecting draft.  
 
        Consider smaller flue size to increase negative draft pressure.