Regency C34-LP2 Manual Do Utilizador
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater
29
COPY OF THE LIGHTING PLATE INSTRUCTIONS
OPERATING INSTRUCTIONS
AERATION ADJUSTMENT
Natural Gas -5/16" (7.9 mm)
Propane - 5/8" (15.9mm)
Propane - 5/8" (15.9mm)
This adjustment is performed by the installer
and is primarily used in installations at high
elevations. Push in for a yellow flame, or pull out
for a bluer flame. The burner aeration is factory
set but may need adjusting due to either the
local gas supply or altitude.
and is primarily used in installations at high
elevations. Push in for a yellow flame, or pull out
for a bluer flame. The burner aeration is factory
set but may need adjusting due to either the
local gas supply or altitude.
Caution: Carbon will be produced if air
shutter is closed too much.
shutter is closed too much.
Note: Aeration Adjustment should only
be performed by an authorized
Regency Installer at the time of
installation or service.
Regency Installer at the time of
installation or service.