Sony MKE-9040M Manual Do Utilizador
1-14
MVE-9000 IM
<Connector>
CN103 (A-4) : TERMINAL pin
This pin is connected to the main CPU control terminal
and used during maintenance.
Conforms to RS-232C.
CN103 (A-4) : TERMINAL pin
This pin is connected to the main CPU control terminal
and used during maintenance.
Conforms to RS-232C.
CN401 (A-5) : TERMINAL pin
This pin is connected to the IEEE1394 control terminal and
used during maintenance.
Conforms to IEEE1394.
This pin is connected to the IEEE1394 control terminal and
used during maintenance.
Conforms to IEEE1394.
CN503 (A-5) : TERMINAL pin
This pin is connected to the COM CPU-1 control terminal
and used during maintenance.
Conforms to RS-232C.
This pin is connected to the COM CPU-1 control terminal
and used during maintenance.
Conforms to RS-232C.
CN703 (A-5) : TERMINAL pin
This pin is connected to the COM CPU-2 control terminal
and used during maintenance.
Conforms to RS-232C.
This pin is connected to the COM CPU-2 control terminal
and used during maintenance.
Conforms to RS-232C.
CN1002 (A-5) : TERMINAL pin
This pin is connected to the S-BUS CPU control terminal
and used during maintenance.
Conforms to RS-232C.
This pin is connected to the S-BUS CPU control terminal
and used during maintenance.
Conforms to RS-232C.
CN1003 (A-3) : ISP common connector
Used only for production in the assembly factory. Used for
program writing into the JTAG device with ISP.
Used only for production in the assembly factory. Used for
program writing into the JTAG device with ISP.
<TEST terminal>
E1 (E-5), E2 (E-1), E3 (C-3), E4 (A-5), E5 (A-1) :
GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.
E1 (E-5), E2 (E-1), E3 (C-3), E4 (A-5), E5 (A-1) :
GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.
TP1 (A-1) :
+
+
+
+
+3.3 V check terminal
+3.3 V measuring terminal.
TP23 (B-1) :
+
+
+
+
+12 V check terminal
+12 V measuring terminal.
TP1301 (A-1) :
+
+
+
+
+5 V check terminal
+5 V measuring terminal.
<LED on the CPU-DR module> : Main CPU
D10 (green) (A-1) : RUN status LED
RUN status indication.
Lit when the CPU-DR module starts operating.
D10 (green) (A-1) : RUN status LED
RUN status indication.
Lit when the CPU-DR module starts operating.
D12 (green) (A-4) : CD (Card Detect) status LED
Lit when the CPU-DR module is inserted correctly into the
parent board.
Lit when the CPU-DR module is inserted correctly into the
parent board.
D13 (green) (A-1) :
+
+
+
+
+2.5 V
Indicates the statue of the
+2.5 V power that is generated
by the VCC (CORE) and supplied to the CPU-DR module.
Lit while the specified power is turned on.
Lit while the specified power is turned on.
D14, D15, D16, D17 (A-3) (green) : STATUS1 to
STATUS4 status LED
Used for maintenance purpose. Only the STATUS1 LED is
lit in normal operation.
STATUS4 status LED
Used for maintenance purpose. Only the STATUS1 LED is
lit in normal operation.
D18 (green) (A-4) :
+
+
+
+
+3.3 V
Indicates the statue of the VCC (I/O) power that is sup-
plied to the CPU-DR module.
Lit while the specified power is turned on.
plied to the CPU-DR module.
Lit while the specified power is turned on.
D19 (green) (A-4) : CORE status LED
Indicates the statue of the VCC (CORE) power that is
supplied to the CPU-DR module.
Lit while the specified power is turned on.
Indicates the statue of the VCC (CORE) power that is
supplied to the CPU-DR module.
Lit while the specified power is turned on.
<Switch on the CPU-DR module> : Main CPU
SW1 (A-1) : RESET switch
Pressing this switch resets the CPU-DR module.
n
In some machines in which the CPU-DR module is
installed, the system reset may be activated.
SW1 (A-1) : RESET switch
Pressing this switch resets the CPU-DR module.
n
In some machines in which the CPU-DR module is
installed, the system reset may be activated.
SW2 (A-2) : MODE switch
8-pin DIP switch
Used only for production in the assembly factory. All
switches are set to OFF for normal operation.
Default setting when shipped from the factory is all OFF.
8-pin DIP switch
Used only for production in the assembly factory. All
switches are set to OFF for normal operation.
Default setting when shipped from the factory is all OFF.